- Name
- Danalock Universal Module Version 3
- Brand
- Danalock
- Features
- Feature Values Supported Notification Types
- Is flirs
- Yes
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_SLEEPING_LISTENING
- User icon
- 0x0300
- Categories
- Locks
- Product id
- 0x0002
- S2 classes
- S2_ACCESS_CONTROL
- Device type
- Door Lock - Keypad
- Oem version
- HW: 2 FW: 1.03:00.06
- Library type
- SLAVE_ENHANCED_232
- Supports nwi
- Yes
- Installer icon
- 0x0300
- Z wave version
- 6.71.01
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x010E
- Product type id
- 0x0009
- Long description
- The Universal Model V3 supports: - S0/S2 Z-Wave Security - Can operate 3 outputs. - Outputs can be delayed. - Bluetooth Smart
- Hardware platform
- ZM5202
- Short description
- Operates garagedoors, doorstrikes, electromechanical or magnetic locks.
- Product identifier
- UMV3-BTZE-EU
- Countries / regions
- European Union
- Certification number
- ZC10-18026026
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 2
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
- Supported notification types
- Notification Type Event / State Access Control
- Value access control firmware updatable value updatable by consumer by rf association groups
- Group Number Maximum Nodes Supported End Point ID Description 1
- From to description 0 2147483647 time before the relay is activated. 3 relay 2 pulse length (ms) time the relay is on in milliseconds. 0 4 0 0 5000 from to description 0 2147483647 time the relay is on in milliseconds. 4 relay 2 delay length (ms) time before the relay is activated. 0 4 0 0 0 from to description 0 2147483647 time before the relay is activated. 5 relay 3 pulse length (ms) time the relay is on in milliseconds. 0 4 0 0 5000 from to description 0 2147483647 time the relay is on in milliseconds. 6 relay 3 delay length (ms) time before the relay is activated. 0 4 0 0 0 from to description 0 2147483647 time before the relay is activated. 8 battery sample interval seconds battery sample interval seconds 0 4 0 0 3600 from to description 0 0 sample off 1 2147483647 seconds between samples 1 relay 1 pulse length (ms) time the relay is on in milliseconds. 0 4 0 0 5000 from to description 0 2147483647 time the relay is on in milliseconds. 7 disable battery alarm disable battery alarm 0 = battery alarm enable, 1 = battery alarm disable 0 1 0 0 0 from to description 0 0 battery alarm enable 1 1 battery alarm disable 9 battery milli volt level threshold maximum maximum battery alarm level in m v. 0 4 0 0 12100 from to description 0 2147483647 maximum battery alarm level in m v. 10 battery milli volt level threshold minimum minimum battery alarm level in m v. 0 4 0 0 11600 from to description 0 2147483647 minimum battery alarm level in m v. 11 ble temporary allow – timer seconds allow bluetooth to be on for a time in seconds 0 4 0 0 0 from to description 0 0 off 1 2147483647 seconds bluetooth smart is on. texts