- Name
- Recessed Door Sensor Gen5
- Brand
- Aeotec
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_SLEEPING_REPORTING
- Categories
- Sensors
- Product id
- 0x0059
- Device type
- Notification Sensor
- Oem version
- HW: 59 FW: 1.13
- Library type
- SLAVE_ENHANCED_232
- Supports nwi
- Yes
- Z wave version
- 6.51.01
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x0086
- Product type id
- 0x0002
- Long description
- The Aeotec by Aeon Labs Recessed Door Sensor Gen5 is a door sensor that can detect the state of the door's open/close. It will report the door state to your controller/ gateway/associated nodes in real time when the state of your door has a change. It’s a security Z-Wave device that supports security encryption. Also it supports the “Over the Air Firmware Updating” that allows you wirelessly update its firmware if needs. It can be included and operated in any Z-Wave network with other Z-Wave certified devices from manufacturers and/or other applications.
- Hardware platform
- ZM5202
- Short description
- Aeon Labs Recessed Door Sensor Gen5 is a door sensor that can detect the state of the door's open/close.
- Association groups
- Group Number Maximum Nodes Supported End Point ID Description 1
- Product identifier
- ZW089-C
- Countries / regions
- European Union
- Certification number
- ZC10-14120011
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 254
- Supports explorer frames
- Yes
- Controlled command classes
- Identifier Name Key Version COMMAND_CLASS_BASIC
- From to description 0 65535 the range of device tag is 65535. 101 enable/disable the function of low battery checking this parameter is used to configure to enable/disable the function of low battery checking.(00==disable, 1==enable). 0 1 0 0 0 from to description 0 0 disable low battery checking. 1 1 enable low battery checking. 252 enable/disable all configuration parameters to be locked this parameter is used to enable/disable all configuration parameters to be locked. (0 =disable, 1 = enable) 0 1 0 0 0 from to description 0 0 disable all configuration parameters to be locked. 1 1 enable all configuration parameters to be locked. 111 the interval time of low battery checking. this parameter is used to configure the interval time of low battery checking. note: 1. the minimum unit of interval time is 4 minutes(240). if the value is set to 1 minute, the interval time will be 4 minutes. the same is if the value is set to 7 minutes, the interval time will be 8 minutes. 2. the possible values are unsigned value, so its range is 0 to 2147483647. 0 4 0 0 86640 from to description 0 2147483647 the range of interval time is 0 to 2147483647. 3 which value of the basic set will be sent when the magnet switch to open/close. this parameter is used to set the basic set value when the magnet switch to open/close. 0 1 0 0 0 from to description 1 1 when the magnet switch to open, basic set=0x00. when the magnet switch to close, basic set=0x ff. 0 0 when the magnet switch to open, basic set=0x ff. when the magnet switch to close, basic set=0x00. 1 which value of the sensor binary report will be sent when the magnet switch to open/close. this parameter is used to set the sensor binary report value when the magnet switch to open/close. 0 1 0 0 0 from to description 0 0 when the magnet switch to open, sensor binary report=0x ff. when the magnet switch to close, sensor binary report=0x00. 1 1 when the magnet switch to open, sensor binary report=0x00. when the magnet switch to close, sensor binary report=0x ff. texts