- Name
- Dry Contact Sensor Gen5
- Brand
- Aeotec
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_SLEEPING_REPORTING
- Categories
- Sensors
- Product id
- 0x0061
- Device type
- Notification Sensor
- Oem version
- HW: 61 FW: 1.05
- Library type
- SLAVE_ENHANCED_232
- Supports nwi
- Yes
- Z wave version
- 6.51.06
- Frequency plans
- US: 916.00MHz, 908.40MHz
- Manufacturer id
- 0x0086
- Product type id
- 0x0102
- Long description
- Aeon Labs Dry Contact Sensor Gen5 is a dry conatct sensor that can detect a variety of dry contact signals, you just need to connect the matched external sensor on it, such as the water level sensor, dry contact switch, dry contact relay and so on. In other words, it can be used if the external sensor is a dry contact. It’s a security Z-Wave device that supports security encryption. Also it supports the “Over the Air Firmware Updating” that allows you wirelessly update its firmware if needs. It can be included and operated in any Z-Wave network with other Z-Wave certified devices from manufacturers and/or other applications.
- Hardware platform
- ZM5202
- Short description
- Aeon Labs Dry Contact Sensor Gen5 is a dry conatct sensor that can detect a variety of dry contact signals.
- Association groups
- Group Number Maximum Nodes Supported End Point ID Description 1
- Product identifier
- ZW097-A
- Countries / regions
- United States of America
- Certification number
- ZC10-15090010
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 1
- Supports explorer frames
- Yes
- Controlled command classes
- Identifier Name Key Version COMMAND_CLASS_BASIC
- From to description 0 0 when the sensor is triggered on, sensor binary report=0x ff. when the sensor is triggered off, sensor binary report=0x00. 1 1 when the sensor is triggered on, sensor binary report=0x00. when the sensor is triggered off, sensor binary report=0x ff. 2 enable/disable wake up 10 minutes when re power on the sensor. this parameter is used to enable/disable wake up 10 minutes when re power on the sensor. 0 1 0 0 1 from to description 0 0 disable. 1 1 enable. 3 which value of the basic set will be sent when the sensor is triggered on/off. this parameter is used to set the basic set value when the sensor is triggered on/off. 0 1 0 0 0 from to description 1 1 when the sensor is triggered on, basic set=0x00. when the sensor is triggered off, basic set=0x ff. 0 0 when the sensor is triggered on, basic set=0x ff. when the sensor is triggered off, basic set=0x00. 111 set the interval time of battery report. this parameter is used to set the interval time of battery report. 0 4 0 0 0 from to description 0 0 the periodic battery report is disabled. 1 2147483647 the range of interval time is 1 seconds to 2147483647 seconds. 122 set a notification type for dry contact sensor. this parameter is used to set a notification type for dry contact sensor. 0 1 0 0 6 from to description 1 1 the smoke alarm notification type is selected for the sensor. 2 2 the co alarm notification type is selected for the sensor. 3 3 the co2 alarm notification type is selected for the sensor. 4 4 the heat alarm notification type is selected for the sensor. 5 5 the water alarm notification type is selected for the sensor. 6 6 the access control notification type is selected for the sensor. 7 7 the home security notification type is selected for the sensor. 8 8 the power management notification type is selected for the sensor. 9 9 the system notification type is selected for the sensor. 10 10 the emergency alarm notification type is selected for the sensor. 11 11 the clock notification type is selected for the sensor. 255 reset the sensor. this parameter is used to reset the sensor. 0 4 0 0 0 from to description 0 0 reset to factory default settings. 1431655765 1431655765 reset to factory default settings and removed from the z wave network. texts