- Name
- Door/ Window Sensor 6
- Brand
- Aeotec
- Features
- Feature Values Firmware Updatable
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_SLEEPING_REPORTING
- User icon
- 0x0C06
- Categories
- Sensors
- Product id
- 0x0070
- Device type
- Notification Sensor
- Oem version
- HW: 112 FW: 1.03
- Library type
- SLAVE_ENHANCED_232
- Supports nwi
- Yes
- Installer icon
- 0x0C06
- Z wave version
- 6.51.10
- Frequency plans
- KR: 920.90MHz, 921.70MHz, 923.10MHz
- Manufacturer id
- 0x0086
- Product type id
- 0x1C02
- Long description
- Door Window Sensor 6 is a sensor binary device based on Z-wave enhanced 232 slave library of V6.51.10. It provides your Z-Wave network with the intelligence required for a modern home automation and security system. And it does it all in a smaller, more elegant design crafted to suit any home's decor. It is also a security Z-Wave device and supports the Over The Air (OTA) feature for the product’s firmware upgrade. It can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. It also supports Security Command Class and has the AES 128 bit security encryption built right in, so a security enabled controller is needed for fully to utilize its function.
- Hardware platform
- ZM5101
- Short description
- Door/ Window Sensor 6 is a smart Z-Wave sensor that can detect the status of door/window's open/close in real time.
- Product identifier
- ZW112-H
- Countries / regions
- Singapore
- Certification number
- ZC10-19026370
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 252
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_SENSOR_BINARY
- Controlled command classes
- Identifier Name Key Version COMMAND_CLASS_BASIC
- Supported multilevel sensors
- Multilevel Sensor Type General purpose
- Supported notification types
- Notification Type Event / State Access Control
- Value updatable by consumer by rf sensors value open/closed (binary) color value white supported notification types value access control association groups
- Group Number Maximum Nodes Supported End Point ID Description 1
- From to description 0 0 unlock. 1 1 lock. 255 reset the sensor. reset the sensor. 0 4 0 0 0 from to description 0 0 reset to default settings. 1431655765 1431655765 reset to default settings and excluded from the network. 1 which value of the sensor binary report or basic set will be sent when the door is opened/closed. to set which value of the sensor binary report or basic set will be sent when the door is opened/closed. 0 1 0 0 1 from to description 0 0 sensor binary report/basic set =0x ff when the door is opened, sensor binary report/basic set= 0x00 when the door is closed. 1 1 sensor binary report/basic set= 0x00 when the door is opened, sensor binary report/basic set=0x ff when the door is closed. 101 enable/disable the function of parameter 111 enable/disable the function of parameter 111. note: this parameter cannot disable the low battery checking of the sensor itself. 0 1 0 0 1 from to description 0 0 disable. 1 1 enable. 111 set the interval time of low battery checking. set the interval time of low battery checking. note: 1, if the value is less than 10, the time unit is second. if the value is more than 10, the time unit is 4 minutes, which means if the value is more than 10 and less than 240, the interval time is 4 minutes. if the value is more than 240 and less than 480, the interval is 8 minutes. 2, if the current battery report falls below the low battery value (configurable parameter 39), it will send battery report=0x ff. 0 4 0 0 86640 from to description 0 2147483647 the range of interval can be set to 0 to 2147483647. 121 to configure which sensor report will be sent when the door is opened/closed. to configure which sensor report will be sent when the door is opened/closed. 0 1 0 0 1 from to description 1 1 basic set cc is selected. 2 2 sensor binary report cc is selected. 3 3 basic set cc and sensor binary report cc are selected. texts