- Name
- Recessed Door Sensor 7
- Brand
- Aeotec
- Features
- Feature Values Battery Quantity
- Documents
- Category Description File Manual_English
- Role type
- ROLE_TYPE_SLAVE_SLEEPING_REPORTING
- User icon
- 0x0C06
- Categories
- Sensors, Security Add-Ons
- Product id
- 0x00BB
- S2 classes
- S2_UNAUTHENTICATED, S2_AUTHENTICATED
- Device type
- Notification Sensor
- Oem version
- HW: 187 FW: 1.01
- Library type
- SLAVE_ENHANCED_232
- Product line
- Z-Wave Plus v2 Line
- Supports nwi
- Yes
- Installer icon
- 0x0C06
- Z wave version
- 7.11.00
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x0371
- Product type id
- 0x0002
- Long description
- 1. Can be embedded inside the wooden door or window. 2. Used to send out notification via Group 1 (Lifeline) when Magnet is away or near. 3. Used to control other Z-Wave device directly via Group 2. 4. Support SmartStart, which makes inclusion more convenient. 5. Support S2, which makes it more secure and reliable.
- Hardware platform
- ZGM130
- Short description
- It can be embedded inside the wooden door or window. Used to send out notification or control other device when Magnet is away or near.
- Product identifier
- ZW187-C
- Countries / regions
- European Union
- Supports smart start
- Yes
- Certification number
- ZC12-19080008
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values Flag Advanced 2
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_CONFIGURATION_V4
- Supported notification types
- Notification Type Event / State Access Control
- Value 1 battery type value cr2 firmware updatable value updatable by consumer by rf color value white association groups
- Group Number Maximum Nodes Supported End Point ID Group Name Profile Description 2
- From to description 0 0 open status when magnet is away, close status when magnet is near. 1 1 close status when magnet is away, open status when magnet is near. 101 timed battery report set how often battery is reported in minutes. 2 2 1 14400 70 from to description 1 14400 set how often battery is reported in minutes. 1 binary sensor report enable/disable binary sensor report. allow for backward compatibility to report binary if notification report cannot be used for status changes. 2 1 0 1 0 from to description 0 0 disable. sensor binary report will not be issued via lifeline when magnet is away or near. 1 1 enable. sensor binary report will be issued via lifeline when magnet is away or near. 81 led indicator control led indicator. determine whether the led flash or not when sending basic set, sensor binary report, notification report (access control) or wake up notification. 2 1 0 3 3 from to description 0 0 completely disable led. 1 1 led quickly flashes only when sending basic set, sensor binary report or notification report (access control). 2 2 led activates only when sending wake up notification. 3 3 led quickly flashes when sending basic set, sensor binary report or notification report (access control), and activates when sending wake up notification. 4 application layer retry configure retry number and wait time. the device supports an application retry mechanism when the application of the device has detected a transmission error when basic set, sensor binary report or notification report (access control) message is sent out but fails to result in an ack or a supervision report. 2 2 0 1535 0 from to description 0 1535 the byte 1 is used to configure the number of retries. the valid value is 0 5. 0 means disable retry. the byte 2 is used to configure the wait time between retries. the valid value is 0 255. unit is 100ms. yes 3 association group 2 settings configure the basic set value. determine the basic set value to control other z wave devices directly when magnet is away or near. 2 1 0 6 1 from to description 0 0 disable completely. 1 1 send basic set 0x ff when magnet is away, and send basic set 0x00 when magnet is near. 2 2 send basic set 0x00 when magnet is away, and send basic set 0x ff when magnet is near. 3 3 only send basic set 0x ff when magnet is away. 4 4 only send basic set 0x00 when magnet is near. 5 5 only send basic set 0x00 when magnet is away. 6 6 only send basic set 0x ff when magnet is near. texts