- Name
- Door/Window Sensor 7
- Brand
- Aeotec
- Features
- Feature Values Battery Quantity
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_SLEEPING_REPORTING
- User icon
- 0x0C06
- Categories
- Sensors
- Product id
- 0x0007
- S2 classes
- S2_UNAUTHENTICATED
- Device type
- Notification Sensor
- Oem version
- HW: 1 FW: 1.00
- Library type
- SLAVE_ENHANCED_232
- Supports nwi
- Yes
- Installer icon
- 0x0C00
- Z wave version
- 6.81.01
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x0371
- Product type id
- 0x0000
- Long description
- Aeotec Door/ Window Sensor 7 is a small window position sensor for your smart home, it monitors window and their exact opening position and lets your know when a window is tilted or completely opened. It also supports connecting external binary sensors through the dry binary contact of the Door/ Window sensor.
- Hardware platform
- ZM5101
- Short description
- Z-Wave Door/ Window Sensor 7.
- Product identifier
- ZWA008-C
- Countries / regions
- European Union
- Certification number
- ZC10-19066568
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 4
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
- Supported multilevel sensors
- Multilevel Sensor Type General purpose
- Supported notification types
- Notification Type Event / State Access Control
- Value 1 battery type value 1/aa color value white firmware updatable value updatable by consumer by rf sensors value open/closed (binary) supported notification types value access control home security power management association groups
- Group Number Maximum Nodes Supported End Point ID Description 4
- From to description 0 0 disabled 1 1 enabled 5 2nd association group trigger his parameter defines the status of the magnet switch that causes sending a basic command to all devices of association group 2. 0 1 0 0 0 from to description 0 0 switch after ‘open‘ and ‘close‘ 1 1 switch after ‘open‘ 2 2 switch after ‘close‘ 6 command sent to devices of association group 2 this parameter defines which commands is sent to 2nd association group 0 1 0 0 2 from to description 0 0 on 1 1 off 2 2 on and off 7 basic command value sent to 2nd association group on ‘on‘ event this is the basic command value sent in case of ‘on‘ event. 0 1 0 0 1 from to description 1 1 value 0 99 value 8 basic command value sent to 2nd association group on ‘off‘ event this is the basic command value sent in case of ‘off‘ event. 0 1 0 0 0 from to description 1 1 value 0 99 value 9 time delay of ‘off‘ command frame off command is sent after a delay defined in this parameter. 0 2 0 0 0 from to description 0 32400 seconds 10 time delay of ‘off‘ command frame off command is sent after a delay defined in this parameter. 0 2 0 0 0 from to description 0 32400 seconds 11 delay of tamper alarm cancellation time a tamper alarm is delayed. 0 2 0 0 0 from to description 0 32400 seconds 1 sensor operation mode this parameter defines if the internal magnet sensor or the external terminal input is detected and used to issue alarm notification. there is always one input active only. the other sensor input the deactivated. 0 1 0 0 0 from to description 0 0 internal magnet sensor used 1 1 external terminal inputs used 2 sensor state polarity this parameter defines the polarity of the magnet sensor. 0 1 0 0 0 from to description 0 0 closed when magnet in proximity 1 1 opened when magnet in proximity texts