- Name
- Water Sensor 7 Pro
- Brand
- Aeotec
- Features
- Feature Values Battery Type
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_SLEEPING_REPORTING
- User icon
- 0x0C05
- Categories
- Sensors
- Product id
- 0x0013
- S2 classes
- S2_UNAUTHENTICATED, S2_AUTHENTICATED
- Device type
- Notification Sensor
- Oem version
- HW: 1 FW: 0.00
- Library type
- SLAVE_ENHANCED_232
- Product line
- Z-Wave Plus v2 Device
- Supports nwi
- Yes
- Installer icon
- 0x0C00
- Z wave version
- 7.12.2
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x0371
- Product type id
- 0x0002
- Long description
- The Water Sensor 7 pro brings more safety into your home. With its flexible sensor probe and the sensitive sensor point it detects the presence and absence of water at any given location. Furthermore the Watersensor 7 pro is enabled to accurately measure the temperature and humidity of its environment, so you are always informed about your room climate. Thanks to the latest Z-Wave 700 series technology, the Water Sensor 7 is distinguished with and increased range, S2 Security, OTA FW update and SmartStart.
- Hardware platform
- ZGM130
- Short description
- The Aeotec Water Sensor 7 Pro detects any liquid, which is spreaded by a leakage or other damage. It also measures the humidity and temperature of its environment.
- Product identifier
- ZWA019-C
- Countries / regions
- European Union
- Supports smart start
- Yes
- Certification number
- ZC12-20060068
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 255
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_CONFIGURATION_V4
- Supported multilevel sensors
- Multilevel Sensor Type Air temperature
- Supported notification types
- Notification Type Event / State Water Alarm
- Value er14250 color value white battery quantity value 1 firmware updatable value updatable by consumer by rf association groups
- Group Number Maximum Nodes Supported End Point ID Group Name Profile Description 4
- From to description 1431655765 1431655765 completely factory reset sensor and send device reset locally notification. 1 1431655764 reset all parameter settings to their default settings. 3 visual led indications this parameter defines when leds will indicate events. disabling all indications may extend battery life. value 0 means no indications. 4 1 0 7 7 from to description 1 0 water leakage status change 2 0 wake up 4 0 device tampering 7 0 all led indications on (values 1 + 2 + 4 summarized) 3 0 water leakage status change + wake up (values 1 + 2) 5 0 water leakage status change + device tampering (values 1 + 4) 6 0 wake up + device tampering (values 2 + 4) 10 time delay of "off" command frame off command is sent after a delay defined in this parameter. 2 2 0 32400 0 from to description 0 32400 seconds 11 delay of tamper alarm cancellation time a tamper alarm is delayed. 2 2 0 32400 0 from to description 0 32400 seconds 4 range test after double click allows to enable the activation of a z wave range test with double clicking the tamper switch. 3 1 0 1 0 from to description 0 0 disabled 1 0 enabled 7 basic command "on event" value this is the basic command value sent in case of "on" event. 2 1 0 255 255 from to description 0 99 value 255 255 value 5 2nd association group trigger this parameter defines the status of the magnet switch that causes sending a basic command to all devices of association group 2. 3 1 0 2 0 from to description 0 0 switch after water leakage start and stop 1 0 switch after water leakage start and stop 2 0 switch after water leakage start and stop 6 command sent to devices of association group 2 this parameter defines which commands is sent to 2nd association group 3 1 0 2 2 from to description 2 0 on and off 1 0 off 0 0 on 8 basic command "off event" value this is the basic command value sent in case of "off" event. 2 1 0 255 0 from to description 255 255 value 0 99 value 9 time delay of "on" command frame on command is sent after a delay defined in this parameter. 2 2 0 32400 0 from to description 0 32400 seconds texts