- Name
- D-Link Z-Wave Motion Sensor
- Brand
- D-Link Corporation
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_SLEEPING_REPORTING
- Categories
- Sensors
- Product id
- 0x000D
- Device type
- Notification Sensor
- Oem version
- 01
- Library type
- SLAVE_ENHANCED_232
- Supports nwi
- Yes
- Z wave version
- 6.51.02
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x0108
- Product type id
- 0x0002
- Long description
- The mydlink Z-Wave Motion Sensor DCH-Z120 has PIR, temperature and illumination, 3 sensors function in one,based on Z-Wave technology.
- Hardware platform
- SD3502
- Short description
- mydlink Z-Wave Motion Sensor 3 in 1 (PIR, Temperature and Illumination)
- Association groups
- Group Number Maximum Nodes Supported End Point ID Description 2
- Product identifier
- DCH-Z120
- Countries / regions
- European Union
- Certification number
- ZC10-14100002
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 9
- Supports explorer frames
- Yes
- Controlled command classes
- Identifier Name Key Version COMMAND_CLASS_BASIC
- From to description 0 127 turn off light time 6 mult sensor function switch multisensor function switch. using bit to control. bit0: reserve. bit1: disable pir integrate illumination to turn on the lighting nodes in the association group 2. (1:disable, 0:enable) bit2: reserve. bit3: reserve. bit4: reserve. bit5: reserve. bit6: reserve. bit7: reserve. notice: the reserve bit is allowed any value, but no effect. 0 1 0 0 4 from to description 2 2 disable pir integrate illumination to turn on the lighting nodes in the association group 2. (1:disable, 0:enable) 3 pir sensitivity pir sensitivity settings. 0 means disable the pir motion. 1 means the lowest sensitivity, 99 means the highest sensitivity. high sensitivity means can detected long distance, but if there is more noise signal in the environment, it will re trigger too frequency. 0 1 0 0 80 from to description 0 99 pir level 8 pir re detect interval time in the normal mode, after the pir motion detected, setting the re detect time. 8 seconds per tick, default tick is 3 (24 seconds). setting the suitable value to prevent received the trigger signal too frequently. also can save the battery energy. notice: if this value bigger than the configuration setting no. 9. there is a period after the light turned off and the pir not start detecting. 0 1 0 0 3 from to description 1 127 pir re detect interval time 2 basic set level setting the basic command value to turn on the light. the 0x ff( 1) means turn on the light. for dimmer equipment 1 to 100 means the light strength. 0 means turn off the light. 0 1 0 0 255 from to description 0 255 basic set value 4 light threshold setting the illumination threshold to turn on the light. when the event triggered and the environment illumination lower then the threshold, the device will turn on the light. 0 means turn off illumination detected function. and never turn on the light. 1 means darkest. 99 means brightest. 100 means turn off illumination detected function. and always turn on the light. notice: in none test mode, only the value in 1 to 99 will enable the illumination detected function and update the illumination value. 0 1 0 0 99 from to description 0 100 light threshold texts