- Name
- Era Inn Edge S AC ZW BD
- Brand
- FIBARO
- Features
- Feature Values Window Covering Control Features
- Documents
- Category Description File Adv_Manual
- Role type
- ROLE_TYPE_SLAVE_ALWAYS_ON
- User icon
- 0x1A00
- Categories
- Motor Control
- Product id
- 0x00BA
- S2 classes
- S2_UNAUTHENTICATED, S2_AUTHENTICATED
- Device type
- Window Covering - Pos/End Aware
- Oem version
- HW: 186 FW: 1.02:01.00
- Library type
- SLAVE_ENHANCED_232
- Product line
- Z-Wave Product Line
- Supports nwi
- Yes
- Installer icon
- 0x1A00
- Z wave version
- 6.81.06
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x010F
- Product type id
- 0x0003
- Long description
- This product supports Security 2 Command Class. While a Security S2 enabled Controller is needed in order to fully use the security feature. This product can be operated in any Z-Wave network with other Z-Wave certified products from other manufacturers. All mains operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. This product supports the Over The Air (OTA) feature for the product's firmware upgrade.
- Hardware platform
- ZM5101
- Short description
- Era Inn Edge S AC ZW BD is a wireless control tubular motor, with knowledge of precise position.
- Product identifier
- E EDGE SI 620 AC ZW BD
- Countries / regions
- European Union
- Supports smart start
- Yes
- Certification number
- ZC10-20046907
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 43
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
- Controlled command classes
- Identifier Name Key Version COMMAND_CLASS_SWITCH_MULTILEVEL_V4
- Supported notification types
- Notification Type Event / State Heat Alarm
- Value position aware manual calibration supports up/down motion firmware updatable value updatable by consumer by rf z wave scene type value scene association groups
- Group Number Maximum Nodes Supported End Point ID Group Name Profile Description 3
- From to description 0 0 sensitivity disabled 1 1 minimum sensitivity 2 2 ultra sensitivity 3 3 ultra sensitivity with brief inversion 4 4 ultra sensitivity with full inversion 165 parameter 9 this parameter allows to check motor hardware reversion and sub revision(read only). 1 4 0 2147483647 0 from to description 0 255 byte4:[lsb] motor hardware sub version. 65536 16777215 byte2:reserved. 16777216 2147483647 byte1:[msb] reserved. 256 65535 byte3:motor hardware version. 70 parameter 8 set a number of moves to start identification. note: when wiggle ends, an unsolicited report to lifeline destination with t he value 0 will be sent. if module receives control command in cc multilevel switch/basic automatically stops the wiggle. 1 2 0 255 0 from to description 0 0 set: stop wiggling; report: wiggling ends. 1 255 set the motor wiggle times and start wiggling. 166 parameter 10 this parameter allows to check motor factory data: gearbox ratio and motor nominal speed(read only). 1 4 0 2147483647 0 from to description 16777216 2147483647 byte1:[msb] reserved. 65536 16777215 byte2:gearbox ratio msb. 0 255 byte4:[lsb] motor norminal speed. 256 65535 byte3:gearbox ratio lsb. 45 parameter 7 this parameter allows to check minimum, maximum and default time of move(read only). note: if value equals to 0x00000000, it means the high or low limit has not been set. 1 4 0 2147483647 0 from to description 0 255 byte4:[lsb] the default time of move (with default speed). 256 65535 byte3:the maximum time of move (with min speed). 65536 16777215 byte2:the minimum time of move (with max speed). 16777216 2147483647 byte1:[msb] reserved. 167 parameter 11 this parameter allows to check motor factory data: motor minimum speed, motor maximum speed and wiggle speed(read only). 1 4 0 2147483647 0 from to description 0 255 byte4:[lsb] wiggle speed. 256 65535 byte3:motor maximum speed. 65536 16777215 byte2:motor minimum speed. 16777216 2147483647 byte1:[msb] reserved. 255 parameter 13 reset configuration parameter 39,41,42,43 to factory setting or factory reset the product. 1 4 0 1431655765 0 from to description 0 0 reset configuration parameter 39,41,42,43 to factory setting. note: configuration report [parameter=255, size=4, value=0x00000000] will be issued via lifeline when this function executed. 1431655765 1431655765 factory reset the product and remove it from the network. note: all configuration parameter will be reset to factory setting. 168 parameter 12 get motor factory data: obstacle detection max level, battery motor and soft start/stop max(read only). 1 4 0 2147483647 0 from to description 16777216 2147483647 byte1:[msb] reserved. 0 255 byte4:[lsb] soft start/stop max. 256 65535 byte2:obstacle detection max level. 65536 16777215 byte3:battery motor. texts