- Name
- FIBARO CO Sensor
- Brand
- FIBARO
- Features
- Feature Values Battery Quantity
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_SLEEPING_REPORTING
- User icon
- 0x0C02
- Categories
- Sensors
- Product id
- 0x1001
- Device type
- Notification Sensor
- Oem version
- HW: 1 FW: 3.02:03.02
- Library type
- SLAVE_ENHANCED_232
- Supports nwi
- Yes
- Installer icon
- 0x0C02
- Z wave version
- 6.51.09
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x010F
- Product type id
- 0x1201
- Long description
- FIBARO CO Sensor is an ultra-light, compact, battery-powered carbon monoxide detector, designed to be placed on a wall. Its high sensitivity allows to detect the presence of the carbon monoxide (CO) gas at the early stage in order to prevent carbon monoxide poisoning. Alarm is signalled with a built-in siren, blinking LED indicator and by sending commands to Z-Wave network devices. Additionally, the device is equipped with a temperature sensor.
- Hardware platform
- ZM5101
- Short description
- FIBARO CO Sensor is a compact, wall-mounted, battery-powered carbon monoxide detector.
- Product identifier
- FGCD-001
- Countries / regions
- European Union
- Certification number
- ZC10-18076178
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 2
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_SENSOR_ALARM
- Controlled command classes
- Identifier Name Key Version COMMAND_CLASS_BASIC
- Supported multilevel sensors
- Multilevel Sensor Type Air temperature
- Supported notification types
- Notification Type Event / State CO Alarm
- Value 1 battery type value cr123 a color value white firmware updatable value updatable by consumer by rf sensors value air temperature carbon monoxide supported notification types value co alarm association groups
- Group Number Maximum Nodes Supported End Point ID Description 1
- From to description 2 2 exceeding the temperature 3 3 both actions enabled 0 0 both actions disabled 1 1 tampering (opened casing) 3 led diode indications this parameter allows to set the actions which result in led diode indications. this parameter does not apply to the most important actions, such as co alarm, malfunction alarm and low battery alarm. 0 1 0 0 0 from to description 0 0 all actions disabled 1 1 tampering (opened casing) 2 2 exceeding the temperature 4 4 lack of z wave range 4 acoustic signals this parameter allows to set the actions which result in acoustic signals. this parameter does not apply to the most important actions, such as co alarm, malfunction alarm and low battery alarm. 0 1 0 0 0 from to description 0 0 all actions disabled 1 1 tampering (opened casing) 2 2 exceeding the temperature 4 4 lack of z wave range 10 commands sent to 2nd association group (co alarm) this parameter defines commands sent to devices associated in 2nd association group (co alarm). values of specified commands may be set in parameters 11 and 12. 0 1 0 0 3 from to description 1 1 basic on 2 2 basic off 3 3 basic on & basic off 11 value of basic on command sent to 2nd association group this parameter defines the value of basic on command sent to devices in 2nd association group after the co alarm activation. 1 99 forcing level of associated devices 255 setting associated devices to the last remembered state or turning them on 0 2 0 0 255 from to description 255 255 setting associated devices to the last remembered state or turning them on 0 99 forcing level of associated devices 17 co level required for sending basic off command to 4th association group this parameter defines the maximum level of co concentration below which falling will result in starting the timer set in parameter 18. 0 2 0 0 25 from to description 10 400 co concentration level in ppm 23 co meter activation this parameter activates reporting the value of co concentration level to the main z wave controller. 0 1 0 0 1 from to description 0 0 disabled 1 1 enabled 25 co level reporting hysteresis this parameter defines a minimum change in co concentration level which results in sending a new value to the main z wave controller. 0 1 0 0 2 from to description 2 6 10 ppm 30 ppm, each 5 ppm 7 associations in z wave network security mode parameter defines how commands are sent in specified association groups: as secure or non secure. parameter is active only in z wave network security mode. it does not apply to 1st “lifeline” association group. parameter 7 values may be combined, e.g. 1+2=3 means that 2nd & 3rd group are sent as secure. 0 1 0 0 63 from to description 1 63 group sent as secure texts