- Name
- FIBARO Smoke Sensor
- Brand
- FIBARO
- Features
- Feature Values Battery Quantity
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_SLEEPING_REPORTING
- User icon
- 0x0C01
- Categories
- Sensors
- Product id
- 0x4002
- Device type
- Notification Sensor
- Oem version
- HW: 2 FW: 3.03:03.03
- Library type
- SLAVE_ENHANCED_232
- Supports nwi
- Yes
- Installer icon
- 0x0C01
- Z wave version
- 6.51.06
- Frequency plans
- RU: 869.00MHz
- Manufacturer id
- 0x010F
- Product type id
- 0x0C02
- Long description
- The FIBARO Smoke Sensor is a universal, ultra-light, perfectly designed, optical Z-Wave smoke detector. Fire alarm is signaled by sound, visual indicator blinking and alarm reports sent to the other devices within Z-wave network. The optical sensor detects smoke at an early stage of fire, often before flames appear and temperature starts to rise significantly. Moreover, the device has a built-in temperature sensor, which is adjustable to allow detection of fire by exceeding given temperature threshold. The FIBARO Smoke Sensor is a battery powered device designed to be placed on the wall or ceiling. Visual indicator signals fire, operating mode and it is used to check if the device is within the Z-wave network using a built-in Z-Wave range tester. The Smoke Sensor is designed to operate in confined spaces, under normal conditions (lacking of smoke, dust or condensed water vapor).
- Hardware platform
- ZM5202
- Short description
- A battery powered smoke detector which gives protection from flaming and smoldering fires.
- Product identifier
- FGSD-002
- Countries / regions
- Russian Federation
- Certification number
- ZC10-17015392
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 2
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_SENSOR_ALARM
- Controlled command classes
- Identifier Name Key Version COMMAND_CLASS_BASIC
- Supported multilevel sensors
- Multilevel Sensor Type Air temperature
- Value 1 battery type value cr123 a firmware updatable value updatable by consumer by rf sensors value air temperature smoke density association groups
- Group Number Maximum Nodes Supported End Point ID Description 1
- From to description 1 1 casing opening notification enabled 0 0 all notifications disabled 2 2 exceeding temperature threshold notification enabled 1 fibaro smoke sensor sensitivity there are 3 levels of sensitivity to smoke presence. level 1 means the highest sesitivity. rising the parameter value lowers the sensitivity to smoke presence. available settings: 1 3 1 high sensitivity 2 medium sensitivity 3 low sensitivity 0 1 0 0 2 from to description 2 2 medium sensitivity 1 1 high sensitivity 3 3 low sensitivity 31 excess temperature signaling interval time interval of signaling (visual indication/sound) excess temperature level. available setting: 1 8640 (multiply by 10 seconds) [10s 24 h] 1 8640 [10s 24h] caution parameter 31 is associated with parameters 2, 3 and 4 settings. their modification may have no effect if configured functionality is not activated in the corresponding parameter. 0 2 0 0 1 from to description 1 8640 [10s 24h] 10 configuration of control frames in basic command class this parameter defines which frames will be sent in the 2 nd association group (smoke alarm). the values of basic on and basic off frames may be defined as described in further parameters. available settings: 0 2 0 basic on & basic off enabled 1 basic on enabled 2 basic off enabled 0 1 0 0 0 from to description 0 0 basic on & basic off enabled 1 1 basic on enabled 2 2 basic off enabled 11 basic on frame value basic on frame is sent in case of smoke presence detection and fire alarm triggering. its value is defined by the parameter. available setting: 0 99, 255 0 turn off the device 1 99 set the device to 1 99 % 255 set the last status 0 2 0 0 255 from to description 0 0 basic off enabled 1 99 set the device to 1 99 % 255 255 set the last status 3 visual indicator notifications status this parameter allows to activate visual indications but does not apply to major alarms, such as fire, trouble and low battery alarm. available settings: 0 7 0 all notifications disabled 1 casing opening notification enabled 2 exceeding temperature threshold notification enabled 4 lack of z wave range notification parameter values may be combined, e.g. 1+2+4=7, means that all notifications are enabled. 0 1 0 0 0 from to description 1 1 casing opening notification enabled 2 2 exceeding temperature threshold notification enabled 0 0 all notifications disabled 4 4 lack of z wave range notification 4 saund notifications status this parameter allows to activate sound signals but does not apply to major alarms, such as fire, trouble and low battery alarm. available settings: 0 7 0 all notifications disabled 1 casing opening notification enabled 2 exceeding temperature threshold notification enabled 4 lack of z wave range notification parameter values may be combined, e.g. 1+2+4=7, means that all notifications are enabled. 0 1 0 0 0 from to description 4 4 lack of z wave range notification 0 0 all notifications disabled 1 1 casing opening notification enabled 2 2 exceeding temperature threshold notification enabled texts