- Name
- FIBARO Smoke Sensor
- Brand
- FIBARO
- Features
- Feature Values Battery Type
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_SLEEPING_REPORTING
- User icon
- 0x0C01
- Categories
- Sensors
- Product id
- 0x7003
- Device type
- Notification Sensor
- Oem version
- HW: 2 FW: 3.03:03.03
- Library type
- SLAVE_ENHANCED_232
- Supports nwi
- Yes
- Installer icon
- 0x0C01
- Z wave version
- 6.51.07
- Frequency plans
- IL: 916.00MHz
- Manufacturer id
- 0x010F
- Product type id
- 0x0C02
- Long description
- The FIBARO Smoke Sensor is a universal, ultra-light, perfectly designed, optical Z-Wave smoke detector. Fire alarm is signalled by sound, visual indicator blinking and alarm reports sent to the other devices within Z-wave network. The optical sensor detects smoke at an early stage of fire, often before flames appear and temperature starts to rise significantly. Moreover, the device has a built-in temperature sensor, which is adjustable to allow detection of fire by exceeding given temperature threshold. The FIBARO Smoke Sensor is a battery powered device designed to be placed on the wall or ceiling. Visual indicator signals fire, operating mode and it is used to check if the device is within the Z-wave network using a built-in Z-Wave range tester. The Smoke Sensor is designed to operate in confined spaces, under normal conditions (lacking of smoke, dust or condensed water vapor). Product video: https://www.youtube.com/watch?v=50QGfkdUtns
- Hardware platform
- ZM5202
- Short description
- A battery powered smoke detector which gives protection from flaming and smoldering fires.
- Product identifier
- FGSD-002
- Countries / regions
- Israel
- Certification number
- ZC10-19076593
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 3
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_SENSOR_ALARM
- Controlled command classes
- Identifier Name Key Version COMMAND_CLASS_BASIC
- Supported multilevel sensors
- Multilevel Sensor Type Smoke density
- Supported notification types
- Notification Type Event / State Smoke Alarm
- Value cr123 a battery quantity value 1 color value white sensors value smoke density supported notification types value smoke alarm association groups
- Group Number Maximum Nodes Supported End Point ID Description 2
- From to description 0 0 all notifications disabled 1 1 casing opening notification enabled 2 2 exceeding temperature threshold notification enabled 4 4 lack of z wave range notification 2 z wave notifications status this parameter allows to activate excess temperature and/or casing opening notifications sent to the main controller. parameter values may be combined, e.g. 1+2=3, means that all notifications are enabled. 0 1 0 0 0 from to description 0 0 all notifications disabled 1 1 casing opening notification enabled 2 2 exceeding temperature threshold notification enabled 10 configuration of control frames in basic command class this parameter defines which frames will be sent in the 2 nd association group (smoke alarm). the values of basic on and basic off frames may be defined as described in further parameters. 0 1 0 0 0 from to description 0 0 basic on & basic off enabled 1 1 basic on enabled 2 2 basic off enabled 11 basic on frame value basic on frame is sent in case of smoke presence detection and fire alarm triggering. its value is defined by the parameter. 0 2 0 0 255 from to description 0 0 turn off the device 1 99 set the device to 1 99% 255 255 set the last status 31 excess temperature signaling interval time interval of signaling (visual indication/sound) excess temperature level 0 2 0 0 1 from to description 1 8640 [10s 24h] 1 fibaro smoke sensor sensitivity there are 3 levels of sensitivity to smoke presence. level 1 means the highest sensitivity. rising the parameter value lowers the sensitivity to smoke presence. 0 1 0 0 2 from to description 2 2 medium sensitivity 3 3 low sensitivity 1 1 high sensitivity 4 sound notifications status this parameter allows to activate sound signals but does not apply to major alarms, such as fire, trouble and low battery alarm. parameter values may be combined, e.g. 1+2+4=7, means that all notifications are enabled. 0 1 0 0 0 from to description 0 0 all notifications disabled 1 1 casing opening notification enabled 2 2 exceeding temperature threshold notification enabled 4 4 lack of z wave range notification texts