- Name
- Leak Gopher Meter Reader
- Brand
- Leak Intelligence, LLC
- Features
- Feature Values Color
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_ALWAYS_ON
- User icon
- 1700
- Categories
- Sensors, Water Valves & Irrigation
- Product id
- 0x0003
- Device type
- Whole Home Meter - Simple
- Oem version
- HW: 255 FW: 1.03
- Library type
- SLAVE_ENHANCED_232
- Supports nwi
- Yes
- Installer icon
- 1700
- Z wave version
- 6.51.07
- Frequency plans
- US: 916.00MHz, 908.40MHz
- Manufacturer id
- 0x0173
- Product type id
- 0x0003
- Long description
- The Leak Gopher Meter Reader is a critical component to protect your home from costly damage due to a water leak. A burst pipe can result many thousands of dollars in repair costs and the Leak Gopher Meter Reader can inform you of the leak in time to prevent damage.
- Hardware platform
- ZM5202
- Short description
- Z-Wave Water Meter Reader with Pulse Count scale for any size meter.
- Product identifier
- LGRM-1
- Countries / regions
- United States of America
- Certification number
- ZC10-16085163
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 3
- Supports explorer frames
- Yes
- Supported / controlled meter types
- Meter Type Rate Type Description Water meter
- Value white firmware updatable value updatable by consumer by rf supported meter type value water association groups
- Group Number Maximum Nodes Supported End Point ID Description 1
- From to description 1 255 1/10ths of an hour 0 0 disabled 1 debounce debounce applies a filter the meter pulse to ensure the meter count is incremented only once with each pulse. the default should work for most meters. if the meter pulses are more than 100/second, then a lower debounce value should be used. if the pulse count is incrementing by more than 1 with each pulse, then the debounce parameter should be increased. note that increasing the debounce value lowers the maximum pulse rate that can be accumulated. for example, a debounce of 100 means any pulse of less than 100ms (1/10th of second) will be filtered out an not counted so the maximum pulse rate that can be accumulated is 5 pulses/sec. 0 1 0 0 10 from to description 1 255 100ms 2 rate count pulse counts are automatically sent to the association group 1 node id every time the pulse count is incremented by value of this parameter. the maximum rate of reports is once per minute so the pulse count can increment by more than this number. a pulse rate of 0 turns off the automatic reporting feature and the system controller has to poll to get the current pulse count. 0 1 0 0 10 from to description 1 255 pulse counts 0 0 disabled texts
- ID Description Value 2