- Name
- Bypass Door Window Sensor Z-Wave 700
- Brand
- LEEDARSON
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_SLEEPING_REPORTING
- User icon
- 0x0c06
- Categories
- Sensors
- Product id
- 0x0041
- S2 classes
- S2_UNAUTHENTICATED, S2_AUTHENTICATED
- Device type
- Notification Sensor
- Oem version
- HW: 1 FW: 1.33
- Library type
- SLAVE_ENHANCED_232
- Product line
- Security
- Supports nwi
- Yes
- Installer icon
- 0x0c06
- Z wave version
- 7.12.2
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x0300
- Product type id
- 0x0300
- Long description
- the door window sensor lets you know when door or windows is opened and can trigger different actions in response to that open action (or close action).
- Hardware platform
- ZGM130
- Short description
- Bypass Door Window Sensor Z-Wave 700
- Association groups
- Group Number Maximum Nodes Supported End Point ID Group Name Profile Description 1
- Product identifier
- 7AA-SS-VE-C0
- Countries / regions
- European Union
- Supports smart start
- Yes
- Certification number
- ZC12-20030038
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 2
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_CONFIGURATION_V4
- Supported notification types
- Notification Type Event / State Access Control
- From to description 1 19200 the average magnetic field. 0x00000001 means that the magnetic field is 1 ut, 0x0002 ee00 means that the magnetic field is 192000 ut 3 7210 pol hyst set the offset about magnetic field range: 0x00000001 0x00002300 or 0x00000001 0x00015 e00 2 4 1 8960 200 from to description 1 8960 the offset of the magnetic field. 0x00000001 means that the magnetic field is 1 ut, 0x0002 ee00 means that the magnetic field is 89600 ut 10 low bat precent this parameter defines a battery level as the “low battery”. range: 0x05 0x32 2 1 5 50 10 from to description 5 50 0x0 a defines the low battery level. 0x05 means that device will send a low level alarm report when the battery levle is less than 5%. 0x32 means that device will send a low level alarm report when the battery levle is less than 50%. 254 lock config enable/disable configuration set 0 – enable. 1 – disable. 1 1 0 1 0 from to description 0 1 parameter 0x fe disable/enable the configuration set function. value 0 means that any configuration set will be disabled, value 1 means that configuration set will be enbale,you can change the values of the configration parameters 1 7210 range set the range about magnetic field range: 0 the range of parameter 0x02 is 0x00000001 0x00004 b00, the range of parameter 0x03 is 0x00000001 0x00002300. 1 the range of parameter 0x02 is 0x00000001 0x0002 ee00, the range of parameter 0x03 is 0x00000001 0x00015 e00. 1 1 0 1 0 from to description 0 1 0 the range of parameter 0x02 is 0x00000001 0x00004 b00 and the range of parameter 0x03 is 0x00000001 0x00002300. 1 the range of parameter 0x02 is 0x00000001 0x0002 ee00 and the range of parameter 0x03 is 0x00000001 0x00015 e00. texts