- Name
- Door/Window-Control
- Brand
- Nice
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_SLEEPING_REPORTING
- User icon
- 0x0C06
- Categories
- Sensors, Window Covering, Security Systems
- Product id
- 0x1000
- Device type
- Notification Sensor
- Oem version
- HW: 2 FW: 3.02
- Library type
- SLAVE_ENHANCED_232
- Product line
- Nice Door/Window-Control
- Supports nwi
- Yes
- Installer icon
- 0x0C06
- Z wave version
- 6.51.09
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x010F
- Product type id
- 0x0702
- Long description
- Door/Window-Control is a wireless, battery powered Hall effect contact sensor, compatible with the Z-Wave Plus™ standard. Changing the device’s status will automatically send signal to the Z-Wave™ controller and associated devices. Sensor can be used to trigger scenes and wherever there is a need for information about opening or closing of doors, windows, garage doors, etc. Opening is detected by separating the sensor’s body and the magnet.In addition, Door/Window-Control is equipped with a built-in temperature sensor.
- Hardware platform
- ZM5101
- Short description
- Door/Window-Control is a wireless, battery powered Hall effect contact sensor, compatible with the Z-Wave Plus™ standard. Changing the device’s status will automatically send signal to the Z-Wave™ controller and associated devices.
- Association groups
- Group Number Maximum Nodes Supported End Point ID Group Name Profile Description 1
- Product identifier
- FGDW-002
- Countries / regions
- European Union
- Certification number
- ZC10-22037075
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 1
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_SENSOR_MULTILEVEL_V5
- Controlled command classes
- Identifier Name Key Version COMMAND_CLASS_BASIC
- Supported multilevel sensors
- Multilevel Sensor Type Air temperature
- Supported notification types
- Notification Type Event / State Heat Alarm
- From to description 0 1 door/window state 6 association for closing value sent value sent to devices in 2nd association group when closing is detected the value of 0 turns off the device, 255 turns it on. in case of associating devices allowing smooth control, values 1 99 allow to set an associated device to a specified level. 1 2 0 255 0 from to description 0 255 association for closing value sent 2 visual led indications this parameter defines events indicated by the visual led indicator. disabling events might extend battery life. 1 1 1 6 6 from to description 1 6 visual led indications 3 associations in z wave network security mode this parameter defines how commands are sent in specified association groups: as secure or non secure. parameter is active only in z wave network security mode. it does not apply to 1st group “lifeline” 1 1 0 3 3 from to description 0 3 associations in z wave network security mode 4 2nd association group triggers parameter defines events which result in sending on/off commands to devices added to the 2nd association group. these commands are sent alternately to switch the devices on and off. 1 1 0 2 0 from to description 0 2 2nd association group triggers 5 association for opening value sent value sent to devices in 2nd association group when opening is detected the value of 0 turns off the device, 255 turns it on. in case of associating devices allowing smooth control, values 1 99 allow to set an associated device to a specified level. 1 2 0 255 255 from to description 0 255 association for opening value sent 7 association for opening time delay time that must elapse from opening to send the command frame to to devices in 2nd association group. 1 2 0 32400 0 from to description 0 32400 association for opening time delay 8 association for closing time delay time that must elapse from closing to send the command frame to devices in 2nd association group. 1 2 0 32400 0 from to description 0 32400 association for closing time delay 9 tamper alarm cancellation delay time period after which a tamper alarm will be cancelled. 1 2 0 32400 5 from to description 0 32400 tamper alarm cancellation delay 10 tamper reporting alarm cancellation reporting cancellation of tamper alarm to the controller and 3rd association group. 1 1 0 1 1 from to description 0 1 tamper reporting alarm cancellation 11 interval of temperature measurements this parameter defines how often the temperature will be measured. the shorter the time, the more frequently the temperature will be measured, but the battery life will shorten. 1 2 0 32400 300 from to description 0 32400 interval of temperature measurements 17 low temperature alarm threshold if temperature is lower than the set value, underheat notification will be sent and low temperature alarm will be triggered (if activated). 1 2 0 599 100 from to description 0 599 low temperature alarm threshold texts