- Name
- Door/window sensor
- Brand
- Sentek
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_SLEEPING_REPORTING
- Categories
- Sensors
- Product id
- 0x0008
- Device type
- Notification Sensor
- Oem version
- 01
- Library type
- SLAVE_ENHANCED_232
- Supports nwi
- Yes
- Z wave version
- 6.51.06
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x0185
- Product type id
- 0x0003
- Long description
- Sentek’s ZC-100 surface mount sensor is a battery-powered Z-Wave magnetic door/window contact sensor for surface mounting. ZC-100 sends radio signals when the Switch and actuate-magnet separate. By taking advantage of Z-Wave mesh network, commands can be routed to their destination via intermediary “listening” Z-Wave products. Products that are Z-Wave certified can be used and communicate with other Z-Wave certified devices. The Sentek Door / Window Sensor is designed for use with scenes in home automation systems, alarm and surveillance systems and everywhere else where information related to opening / closing of doors, windows, garage gates, etc. is needed. Suitable for smart home systems.
- Hardware platform
- ZM5202
- Short description
- ZC-100 surface mount sensor is a battery-powered Z-Wave magnetic door/window contact sensor which is used to indicated the door/window on-off status.
- Association groups
- Group Number Maximum Nodes Supported End Point ID Description 1
- Product identifier
- ZC-100
- Countries / regions
- European Union
- Certification number
- ZC10-15090019
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 1
- Supports explorer frames
- Yes
- Controlled command classes
- Identifier Name Key Version COMMAND_CLASS_BASIC
- From to description 0 1 led controll 0 0 4 type of in input available parameter settings: 0 – input no (normal open) 1 – input nc (normal close) 0 1 0 0 0 from to description 0 1 type of in input 0 0 5 type of control frame transmitted, activated via in input. the parameter allows you to specify the type of an alarm frame or to force control frames transmission (basic set) default value: 255 – basic set available parameter settings: 1 – alarm smoke frame 2 – alarm co frame 3 – alarm co2 frame 4 – alarm overheat frame 5 – alarm water frame 255 – control frame basic set 0 1 0 0 255 from to description 1 5 the type of an alarm frame 255 255 force control frames transmission (basic set) texts
- ID Description Value 1