- Name
- Building 36 Temperature Sensor
- Brand
- Building 36
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_SLEEPING_REPORTING
- Categories
- Sensors
- Product id
- 0x0001
- Device type
- Multilevel Sensor
- Oem version
- 01
- Library type
- SLAVE_ENHANCED_232
- Supports nwi
- Yes
- Z wave version
- 6.51.06
- Frequency plans
- US: 916.00MHz, 908.40MHz
- Manufacturer id
- 0x0190
- Product type id
- 0x0003
- Long description
- Battery powered indoor Z-Wave temperature sensor. Sense temperature in any room in the home.
- Hardware platform
- ZM5202
- Short description
- Battery powered Z-Wave temperature sensor.
- Association groups
- Group Number Maximum Nodes Supported End Point ID Description 1
- Product identifier
- B36-S10
- Countries / regions
- United States of America
- Certification number
- ZC10-16010010
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 4
- Supports explorer frames
- Yes
- From to description 0 0 if zero, sensor will not send unsolicted temperature reports 2 2 if bit 1 is set, sensor will send unsolicited temperature reports when the temperature changes. 5 battery reporting interval the number wakeup intervals between autonomous battery reports. 0 2 0 0 8 from to description 0 0 0 255 number of wake up intervals between autonomous battery reports. the wake up interval is set in the wake up command class. 6 temperature checking interval the number of seconds between temperature readings. 0 2 0 0 60 from to description 0 0 10 255 the number of seconds between temperature readings 8 temperature calibration offset adjust reported temperature by +/ 10 degrees fahrenheit for calibration. 0 2 0 0 0 from to description 100 100 tenths of a degree fahrenheit. a value of 10 would be 1.0 f. 0 0 9 mandatory temperature reporting interval temperature will be reported regardless of differential from threshold. 0 2 0 0 7200 from to description 60 64800 the number of seconds between temperature reports. 0 0 1 wake up period number of seconds the sensor will stay in the wake up state following a button press. the sensor will go to sleep if it receives a wake up no more information frame. 0 2 0 0 600 from to description 0 0 10 32768 seconds to stay awake following button press 2 low battery level low battery report threshold. 0 2 0 0 1755 from to description 1000 2500 battery level 0 0 7 temperature reporting interval the number wakeup intervals between autonomous temperature reports. these interval reports should be sent regardless of the setting of the temperature reporting threshold. 0 2 0 0 0 from to description 0 255 the number of wake up intervals between autonomous temperature reports. if this value is zero, autonomous temperature reporting based on wake up interval is disabled. 0 0 3 temperature reporting threshold the minimum temperature difference required to send a new ambient temperature report. 0 2 0 0 10 from to description 0 0 0 100 tenths of a degree fahrenheit. a value of 10 would be 1.0 f. texts