- Name
- Siren Alarm
- Brand
- Coolcam
- Features
- Feature Values Battery Type
- Is flirs
- Yes
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_SLEEPING_LISTENING
- User icon
- 0x0F00
- Categories
- Security Add-Ons
- Product id
- 0x0088
- Device type
- Siren
- Oem version
- HW: 48 FW: 2.65
- Library type
- SLAVE_ROUTING
- Supports nwi
- Yes
- Installer icon
- 0x0F00
- Z wave version
- 6.51.08
- Frequency plans
- US: 916.00MHz, 908.40MHz
- Manufacturer id
- 0x0258
- Product type id
- 0x0003
- Long description
- In the front casing, there is button that is used to carry out include, exclude or reset factory default settings on PCB Board. When power is first supplied, the LED will flash on and off alternately at one second intervals within 5 seconds if the detector has not been added a Z‐Wave network. Please get familiar with the terms below before starting the operations. This product can be included and operated in any Z‐Wave network with other Z‐Wave certified devices from other manufacturers and/or other applications. All non‐battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
- Hardware platform
- ZM5202
- Short description
- This product can be included and operated in any Z‐Wave network with other Z‐Wave certified devices from other manufacturers and/or other applications. All non‐battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
- Product identifier
- NAS-AB01Z
- Countries / regions
- United States of America
- Certification number
- ZC10-16105297
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 3
- Supports explorer frames
- Yes
- Value cr123 a color value white communications connections value rs 232 (serial) communications protocol value z wave serial api firmware updatable value updatable by manufacturer z wave scene type value scene battery quantity value 2 association groups
- Group Number Maximum Nodes Supported End Point ID Description 1
- From to description 0 255 unsigned 1 configure alarm music volume this parameter defines the output volume when siren plays door bell music. door bell music volume is divided into 3 stages, low (parameter is set to ‘1’), middle (parameter is set to ‘2’), high (parameter is set to ‘3’). default value is ‘3’. 0 1 0 0 3 from to description 1 3 unsigned 4 configure door bell music volume this parameter defines the output volume when siren plays alarm music. door bell music volume is divided into 3 stages, low (parameter is set to ‘1’), middle (parameter is set to ‘2’), high(parameter is set to ‘3’). default value is ‘1’. 0 1 0 0 1 from to description 1 3 unsigned 5 configure alarm music index this parameter defines the alarm music index for siren play different music when alarm occurs. there are 10 different music for user selection. 0 1 0 0 10 from to description 1 10 unsigned 6 configure door bell music index this parameter defines the door bell music index for siren play different music when alarm occurs. there are 10 different music for user selection. 0 1 0 0 9 from to description 1 10 unsigned 8 configure alarm led enable this parameter defines the default led enable status when siren is on for alarm music mode. if parameter is set to ‘0’, led will be disable. if parameter is set t0 ‘1’, led will be enable. when siren is on, the led will blink. 0 1 0 0 1 from to description 0 1 unsigned 9 configure door bell led enable this parameter defines the default led enable status when siren is on for door bell music mode. if parameter is set to ‘0’, led will be disable. if parameter is set t0 ‘1’, led will be enable. when siren is on, the led will blink. 0 1 0 0 0 from to description 0 1 unsigned 2 configure alarm music duration time this parameter defines the alarm music duration time when siren receive an alarm sensor notification report or an alarm command from controller. the duration time is divided into 5 stages: siren is not on (parameter is set to ‘0’), 30 second (parameter is set to ‘1’), 1 minute (parameter is set to ‘2’), 5 minute (parameter is set to ‘3’) and siren is always on until battery is dead (parameter is set to ‘255’). default value is ‘2’. 0 1 0 0 2 from to description 0 3 unsigned 255 255 unsigned 7 configure default siren on mode this parameter defines the default music index, volume and the duration time forsiren on. this parameter can be selected between alarm music and door bell music. the settings for alarm music mode defines by param #1, #2 and #5. the settings for door bell music mode defines by param #3, #4 and #6. if parameter is set to ‘1’, siren will select alarm music mode to play music; if parameter is set to ‘2’, siren will select door bell music mode to play music; 0 1 0 0 1 from to description 1 2 unsigned texts