- Name
- PIR Motion Sensor
- Brand
- Golden Security
- Features
- Feature Values Switch Load Capacity Watts
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_SLEEPING_REPORTING
- User icon
- 0x0C07
- Categories
- Sensors, Security Add-Ons
- Product id
- 0x0100
- S2 classes
- S2_UNAUTHENTICATED
- Device type
- Notification Sensor
- Oem version
- HW: 17 FW: 1.80
- Library type
- SLAVE_ENHANCED_232
- Supports nwi
- Yes
- Installer icon
- 0x0C07
- Z wave version
- 6.71.01
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x033A
- Product type id
- 0x0003
- Long description
- This product can be included and operated in any Z-Wave™ network with other Z-Wave™ certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
- Hardware platform
- ZM5202
- Short description
- This sensor has motion detector, ambient temperature and ambient humidity sensor in one which based on Z-Wave™ Plus technology.
- Product identifier
- GS-ZWMS08
- Countries / regions
- European Union
- Certification number
- ZC10-18015965
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 2
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_POWERLEVEL
- Controlled command classes
- Identifier Name Key Version COMMAND_CLASS_BASIC
- Supported multilevel sensors
- Multilevel Sensor Type Air temperature
- Supported notification types
- Notification Type Event / State Home Security
- Value 0.108 switch load capacity current value 1300m a color value white battery quantity value 1 supported notification types value home security battery type value cr123 a switch load capacity volt ampere value 3 v sensors value motion/no motion (binary) air temperature humidity association groups
- Group Number Maximum Nodes Supported End Point ID Description 1
- From to description 0 3 window time = [value] * 4s + 4s 3 pulse count this parameter is configured amount of pulses during the specified time window which trigger a motion event. 0 1 0 0 1 from to description 0 3 amount of pluses = [value] + 1. 5 motion enable this parameter is configured the motion detected if enable or not. if ‘1’, motion detected function is enable. otherwise is disabled. 0 1 0 0 1 from to description 0 0 motion detected function is disabled 1 1 motion detected function is enable 1 motion sensitivity this parameter is configured the sensitivity that motion detect. 0 1 0 0 1 from to description 1 100 this value is larger, the sensitivity is lower, and the distance for motion detecting is closer. 8 led indicate enable this parameter is configured the led light on disable or enable. 0 1 0 0 1 from to description 0 0 disable led blink. this configuration is not affecting inclusion, exclusion and reset. 1 1 enable led blink when device detects a motion event. 7 motion event re trigger enable this configuration sets motion event re trigger is enabled or disabled. 0 1 0 0 0 from to description 0 0 disabled. the motion event will be sent to controller only when the last motion event is cleared. 1 1 enabled. the time interval for motion event detecting is defined by configuration no. 4. 9 binary sensor report enable this configuration sets binary sensor report is enabled or disabled. 0 1 0 0 0 from to description 0 0 disable sensor binary report when device detects a motion event. 1 1 enable sensor binary report when device detects a motion event. 10 basic set level this parameter is configured the value that basic set for nodes that associated in group 2, 3, 4. ‘100’ – basic set = 0x ff (on). ‘0’ – basic set = 0x00 (off). 0 1 0 0 100 from to description 0 99 basic set = 0x00 ~ 0x63 100 100 basic set = 0x ff 17 high level temperature threshold this parameter is configured the threshold value that high level for temperature. when the current ambient temperature value is larger than this configuration value, this will trigger a basic set = [value] (the value is decided by configuration parameter 10) to control the devices in group 3. otherwise, the basic set = 0x00 will be sent to devices in group 3 if these devices have been set to ‘on’. 0 2 0 0 300 from to description 0 500 high level value =value x 0.1℃ texts