- Name
- Multisensor
- Brand
- Hank
- Features
- Feature Values Color
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_SLEEPING_REPORTING
- User icon
- 0x0C07
- Categories
- Sensors
- Product id
- 0x0006
- Device type
- Notification Sensor
- Oem version
- HW: 1 FW: 1.04
- Library type
- SLAVE_ENHANCED_232
- Supports nwi
- Yes
- Installer icon
- 0x0C07
- Z wave version
- 6.51.09
- Frequency plans
- US: 916.00MHz, 908.40MHz
- Manufacturer id
- 0x0208
- Product type id
- 0x0201
- Long description
- Multisensor is a universal Z-Wave device. Along with detecting motion the device measures the temperature, humidity and luminance . It can communicate with associated Z-Wave devices, such as Siren, Smart Switch, etc.
- Hardware platform
- ZM5101
- Short description
- Multisensor is a universal Z-Wave device. Along with detecting motion the device measures the temperature, humidity and luminance .
- Product identifier
- HKZW-MS01
- Countries / regions
- United States of America
- Certification number
- ZC10-17035508
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 170
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_SENSOR_MULTILEVEL_V5
- Controlled command classes
- Identifier Name Key Version COMMAND_CLASS_BASIC
- Supported multilevel sensors
- Multilevel Sensor Type General purpose
- Supported notification types
- Notification Type Event / State Access Control
- Value white firmware updatable value updatable by consumer by rf battery type value cr123 a sensors value motion/no motion (binary) luminance humidity supported notification types value access control battery quantity value 2 association groups
- Group Number Maximum Nodes Supported End Point ID Description 2
- From to description 85 85 set parameter 171,172,173,174 to default settings 171 battery report interval the interval of sending battery report to association device (group lifeline). the reports are sent even if there are no changes in the battery level. 0 4 0 0 1800 from to description 5 2678400 the interval of sending battery report 172 temperature report interval the interval of sending temperature report to association device (group lifeline). the reports are sent even if there are no changes in the temperature level. 0 4 0 0 1800 from to description 5 2678400 the interval of sending temperature report 173 humidity report interval the interval of sending humidity report to association device (group lifeline). the reports are sent even if there are no changes in the humidity level. 0 4 0 0 1800 from to description 5 2678400 the interval of sending humidity report 174 luminance report interval the interval of sending luminance report to association device (group lifeline). the reports are sent even if there are no changes in the luminance level. 0 4 0 0 1800 from to description 5 2678400 the interval of sending luminance report 181 battery report threshold the parameter determines the change in battery level resulting in battery report being sent to the main controller. 0 1 0 0 10 from to description 0 100 the change in battery level resulting in battery report being sent to the main controller. 183 humitidy report threshold the parameter determines the change in humidity level resulting in humidity report being sent to the main controller. 0 1 0 0 5 from to description 0 0 reports are not sent 1 255 the change in humidity level resulting in humidity report being sent to the main controller. 184 luminance report threshold the parameter determines the change in luminance level resulting in luminance report being sent to the main controller. 0 2 0 0 200 from to description 0 0 reports are not sent 1 65535 the change in luminance level resulting in luminance report being sent to the main controller. texts