- Name
- Smart Plug
- Brand
- Hank
- Features
- Feature Values Switch Load Capacity Current
- Documents
- Category Description File Image_Product_Supplemental_3
- Role type
- ROLE_TYPE_SLAVE_ALWAYS_ON
- User icon
- 0x0700
- Categories
- All Lighting Devices, On/Off Switches/Devices
- Product id
- 0x0022
- S2 classes
- S2_UNAUTHENTICATED
- Device type
- On/Off Power Switch
- Oem version
- HW: 1 FW: 1.02
- Library type
- SLAVE_ENHANCED_232
- Product line
- 5P
- Supports nwi
- Yes
- Installer icon
- 0x0700
- Z wave version
- 6.81.01
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x0208
- Product type id
- 0x0100
- Long description
- Smart Plug is a Z-Wave Switch plugin module specifically used to enable Z-Wave command and control (on/off) of any plug-in tool. It can report wattage consumption or kWh energy usage. This device is a security enabled Z-Wave Plus product that is able to use encrypted Z-Wave Plus messages to communicate to other security enabled Z-Wave Plus products. Smart Plug is also a security Z-Wave device and supports the Over The Air (OTA) feature for the product’s firmware upgrade. This device must be used in conjunction with a Security Enabled Z-Wave Controller in order to fully utilize all implemented functions. Features: 1) AC output switch on/off by manual or Z-Wave command; 2) RGB LED indicates the Z-WAVE network range and load power; 3) Support S0 and S2 security network; 4) Supporting power meter; 5) Supporting repeater role; 6) Supporting firmware OTA; 7) Supporting Smart Start; 8) Supports over-current protection
- Hardware platform
- ZM5202
- Short description
- Smart Plug is a Z-Wave Switch plugin module specifically used to enable Z-Wave command and control (on/off) of any plug-in tool.
- Product identifier
- HKZW-SO13
- Countries / regions
- European Union
- Supports smart start
- Yes
- Certification number
- ZC10-19116791
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 24
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_SCENE_ACTUATOR_CONF
- Supported / controlled meter types
- Meter Type Rate Type Description Electric meter
- Value 16 a switch load capacity volt ampere value 230 v switch load capacity watts value 3680 w firmware updatable value updatable by consumer via internet neutral wire required switch type value push button with indicator communications protocol value z wave serial api color value white electric load type value incandescent fluorescent mlv (magnetic) elv (electronic) led dimmable led inductive (e.g. motor) dimmable fluorescent dimmable mlv (magnetic) dimmable elv (magnetic) supported meter type value electric energy association groups
- Group Number Maximum Nodes Supported End Point ID Group Name Profile Description 1
- From to description 0 0 the function is disabled. 1 1 send basic report. 2 2 send basic report only when load condition is not changed by z wave command. 151 threshold of power report power threshold to be interpreted, when the change value of load power exceeds the setting threshold, the smart plug will send meter report to association device (group lifeline). 0 2 0 0 50 from to description 0 200 available settings: 0 200 (0 200 w) 0 0 0 the function is disabled. 152 percentage threshold of power report power percentage threshold to be interpreted, when change value of the load power exceeds the setting threshold, the smart plug will send meter report to association device (group lifeline). 0 1 0 0 10 from to description 0 0 the function is disabled. 0 100 available settings: 0 100 (0 100%) 171 power report frequency the interval of sending power report to association device (group lifeline). 0 4 0 0 3600 from to description 0 0 the function is disabled. 3600 2678400 available settings: 3600 2678400 (3600 2678400s) 172 energy report frequency the interval of sending energy report to association device (group lifeline). 0 4 0 0 7200 from to description 0 0 the function is disabled. 3600 2678400 available settings: 3600 2678400 (3600 2678400s) 173 voltage report frequency the interval of sending voltage report to association device (group lifeline). 0 4 0 0 0 from to description 0 0 the function is disabled. 3600 2678400 available settings: 3600 2678400 (3600 2678400s) 174 electricity report frequency the interval of sending electricity report to association device (group lifeline). 0 4 0 0 0 from to description 3600 2678400 available settings: 3600 2678400 (3600 2678400s) 0 0 the function is disabled. 254 enable/disable the configuration command lock/unlock all configuration parameters. 0 1 0 0 0 from to description 1 1 lock 0 0 unlock texts