- Name
- KONOzw Smart Hub Thermostat
- Brand
- LUX
- Features
- Feature Values Color
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_ALWAYS_ON
- User icon
- 0x1200
- Categories
- Thermostats, HVAC
- Product id
- 0x2111
- S2 classes
- S2_UNAUTHENTICATED, S2_AUTHENTICATED
- Device type
- Thermostat - HVAC
- Oem version
- HW: 2 FW: 1.00:00.114
- Library type
- SLAVE_ENHANCED_232
- Supports nwi
- Yes
- Installer icon
- 0x1200
- Z wave version
- 6.71.03
- Frequency plans
- US: 916.00MHz, 908.40MHz
- Manufacturer id
- 0x0411
- Product type id
- 0x0001
- Long description
- KONOzw is the smart hub thermostat made with you in mind. It seamlessly connects to many smart hubs and blends in or stands out with its interchangeable Décorsnap covers™. KONOzw makes it easier than ever to personalize your comfort, décor, and savings.
- Hardware platform
- ZM5202
- Short description
- KONOzw battery powered or 24Vac wireless thermostat
- Product identifier
- KN-ZW-WH1-B04
- Countries / regions
- United States of America
- Certification number
- ZC10-19076681
- Configuration parameters
- Parameter Number Name Format Size Min Value Max Value Default Value Parameter Values Description 5
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_POWERLEVEL
- Supported multilevel sensors
- Multilevel Sensor Type Air temperature
- Supported notification types
- Notification Type Event / State Power Management
- Value white firmware updatable value updatable by manufacturer loads controlled value 4 sensors value air temperature supported notification types value power management switch load capacity current value 1.5 a max output rating per terminal switch load capacity volt ampere value 30 va 1.5 a max output rating per terminal thermostat hvac systems supported value heat only cool only multi stage heat pump thermostat power source value battery power stealing (hard wired 24 v) battery type value aa battery quantity value 4 thermostat modes value heat cool auto auxiliary/emergency heat fan only furnace auto changeover away association groups
- Group Number Maximum Nodes Supported End Point ID Description 1
- From to description 0 0 o valve 1 1 b valve 4 system type 0 1 0 0 0 from to description 0 0 furnace gas 1 1 furnace electric 2 2 heat pump 3 3 boiler no fan 4 4 reserved 8 temperature limit heat max 0 2 0 0 90 from to description 60 90 increment by 1 f 2 temperature unit (c/f) 0 1 0 0 1 from to description 0 0 celsius 1 1 fahrenheit temperature unit (c/f) 3 available control mode 0 1 0 0 0 from to description 0 0 heat and cool, auto 1 1 heat only 2 2 cool only 3 3 heat and cool, no auto 4 4 reserved available control mode 9 temperature limit heat min 0 2 0 0 45 from to description 45 60 increment by 1 f 11 temperature limit cool min 0 2 0 0 50 from to description 50 75 increment by 1 f. the actual allowable range is dependent on the heat set point limit 10 temperature limit cool max 0 2 0 0 95 from to description 60 95 increment by 1 f. the actual allowable range is dependent on the heat set point limit 17 command echo enable 0 1 0 0 0 from to description 0 0 disable 1 1 enable command echo for thermostat mode thermostat fan mode thermostat setpoint 1 user temperature calibration 0 2 0 0 0 from to description 250 250 step size = 10 user temperature calibration. for example, sending a value of +50 means the calibration offset is +0.5 f texts
- ID Description Value 1