- Name
- 9 in 1 MULTI-SENSOR
- Brand
- MCO Home
- Features
- Feature Values Color
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_ALWAYS_ON
- User icon
- 0x0DFF
- Categories
- Sensors
- Product id
- 0x135A
- S2 classes
- S2_UNAUTHENTICATED
- Device type
- Notification Sensor
- Oem version
- HW: 255 FW: 6.00
- Library type
- SLAVE_ENHANCED_232
- Product line
- AIR QUALITY SENSOR
- Supports nwi
- Yes
- Installer icon
- 0x0D00
- Z wave version
- 6.71.03
- Frequency plans
- US: 916.00MHz, 908.40MHz
- Manufacturer id
- 0x015F
- Product type id
- 0xA803
- Long description
- MCOHome A8-9 is a Z-Wave™ enabled multiple environmental monitoring sensor, with 3.5 inch TFT clear display and compliant to Z-Wave Plus™ standard. It is built in with Temperature, Humidity, PM2.5, CO2, VOC, PIR, illumination, Noise, Smoke sensor. Device can be added into any Z-Wave™ network, and is compatible with any other Z-Wave™ certified devices.
- Hardware platform
- ZM5202
- Short description
- MCOHome A8-9 is a Z-Wave™ enabled multiple environmental monitoring sensor.
- Product identifier
- A8-9
- Countries / regions
- United States of America
- Certification number
- ZC10-20096971
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 6
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
- Supported multilevel sensors
- Multilevel Sensor Type Illuminance
- Value white association groups
- Group Number Maximum Nodes Supported End Point ID Group Name Profile Description 1
- From to description 0 32767 value=0 indicates turn off report , value>=1 indicates to report current illumination value when change >n*1 lux 1 parameter 1 this is the pm2.5 delta level which determine when to report the current pm2.5 value. 1 1 0 127 0 from to description 0 127 value=0 indicates turn off report , value>=1 indicates to report current pm2.5 value when change > n * 1ug/m3 9 parameter 9 this is the smoke delta level which determines when to report the current smoke value. 1 1 0 1 1 from to description 0 1 value=0 indicates turn off report , value=1 indicates report change 3 parameter 3 this is the temperature delta level which determines when to report the current temperature value. 1 1 0 127 0 from to description 0 127 value=0 indicates turn off report , value>=1 indicates to report current temperature value when change > n * 0.5℃ 7 parameter 7 this is the d b delta level which determines when to report the current noise value. 1 1 0 127 0 from to description 0 127 value=0 indicates turn off report , value>=1 indicates to report current noise value when change >n*1 d b 4 parameter 4 this is the humidity delta level which determines when to report the current humidity value. 1 1 0 127 0 from to description 0 127 value=0 indicates turn off report , value>=1 indicates to report current humidity value when change >n% 8 parameter 8 this is the pir delta level which determines when to report the current pir value. 1 1 0 1 0 from to description 0 1 value=0 indicates turn off report , value=1 indicates report change 5 parameter 5 this is the voc delta level which determines when to report the current voc value. 1 1 0 127 0 from to description 0 127 value=0 indicates turn off report , value>=1 127*5ppb report change 2 parameter 2 this is the co2 delta level which determines when to report the current co2 value. 1 1 0 127 0 from to description 0 127 value=0 indicates turn off report , value>=1 indicates to report current co2 value when change > n * 5ppm texts