- Name
- Flood Multisensor
- Brand
- Philio
- Features
- Feature Values Firmware Updatable
- Documents
- Category Description File Manual_English
- Role type
- ROLE_TYPE_SLAVE_SLEEPING_REPORTING
- User icon
- 0x0C05
- Categories
- Sensors
- Product id
- 0x0078
- S2 classes
- S2_UNAUTHENTICATED
- Device type
- Notification Sensor
- Oem version
- HW: 1 FW: 1.01:01.14
- Library type
- SLAVE_ENHANCED_232
- Product line
- Philio Z-wave Products
- Supports nwi
- Yes
- Installer icon
- 0x0C05
- Z wave version
- 6.81.03
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x013C
- Product type id
- 0x0002
- Long description
- This product can be included and operated in any Z-Wave TM network with other Z-Wave TM certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
- Hardware platform
- SD3502
- Short description
- The flood multisensor PAT02 has flood, temperature and humidity, 3 sensors function in one, based on Z-Wave TM technology.
- Product identifier
- PAT02-A
- Countries / regions
- European Union
- Supports smart start
- Yes
- Certification number
- ZC10-20026862
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 1
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
- Controlled command classes
- Identifier Name Key Version COMMAND_CLASS_BASIC
- Supported multilevel sensors
- Multilevel Sensor Type Air temperature
- Supported notification types
- Notification Type Event / State Water Alarm
- Value not updatable association groups
- Group Number Maximum Nodes Supported End Point ID Group Name Description 1
- From to description 127 127 setting the basic command value. 2 basic set on level setting the basic command value. when the flood trigger on(0x ff), send the basic cc to the group 2. 1 1 127 127 1 from to description 127 127 setting the basic command value. 6 mult sensor function switch multisensor function switch. using bit to control. 1 1 127 127 0 from to description 64 64 disable the humidity report after event triggered. 7 customer function customer function switch, using bit control. 1 1 127 127 0 from to description 8 8 disable send out basic off after the flood event cleared. 64 64 disable to report battery state when the device triggered. 23 humidity differential report the humidity differential to report. 1 1 0 60 5 from to description 0 60 the unit is percentage. texts
- ID Description Value 8