- Name
- Range Extender EU
- Brand
- Ring
- Features
- Feature Values Color
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_ALWAYS_ON
- User icon
- 0x1B00
- Categories
- Network Devices
- Product id
- 0x0202
- S2 classes
- S2_UNAUTHENTICATED, S2_AUTHENTICATED
- Device type
- Repeater
- Oem version
- HW: 1 FW: 3.05
- Library type
- SLAVE_ENHANCED_232
- Product line
- DIY Security System
- Supports nwi
- Yes
- Installer icon
- 0x1B00
- Z wave version
- 6.81.03
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x0346
- Product type id
- 0x0401
- Long description
- Range Extenders extend the signal from your Alarm Base Station to all its components, so you can make sure your entire system stays online - Requires the Ring Alarm Security Kit. The Ring Extender is a Z-Wave range extender with battery backup. It is a Security Enabled Z-Wave Plus Product and requires a security-enabled Z-Wave Plus controller to make use of all of its features. It will repeat Z-Wave commands from all nodes in the network, from any certified Z-Wave device manufacturer. Any non-battery powered Z-Wave device will also repeat signals in a Z-Wave network.
- Hardware platform
- ZM5101
- Short description
- The Ring Extender is a Z-Wave range extender with battery backup. It is a Security Enabled Z-Wave Plus product and requires a security-enabled Z-Wave Plus controller to make use of all of its features.
- Product identifier
- 4AR1E9-0EU0
- Countries / regions
- European Union
- Supports smart start
- Yes
- Certification number
- ZC10-19106784
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 4
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
- Supported notification types
- Notification Type Event / State Power Management
- Value white association groups
- Group Number Maximum Nodes Supported End Point ID Group Name Description 1
- From to description 1 60 the number base seconds used in the calculation for sleeping between retry messages. 5 supervision battery report the number of battery report messages sent before being encapsulated in supervision. 1 1 0 31 5 from to description 0 31 the number of battery report messages sent before being encapsulated in supervision. 6 build number the jenkins build number for this fw 1 4 0 0 0 from to description 0 0 the jenkins build number for this fw 1 battery report interval this parameter is the number of minutes between heartbeats. heartbeats are automatic battery reports on a timer after the last event. 1 1 4 70 70 from to description 4 70 this parameter is the number of minutes between heartbeats. heartbeats are automatic battery reports on a timer after the last event. 3 supervision retry number of application level retries attempted for messages either not acked or messages encapsulated via supervision get that did not receive a report. 1 1 0 5 1 from to description 0 5 number of application level retries attempted for messages either not acked or messages encapsulated via supervision get that did not receive a report. texts
- ID Description Value 8