- Name
- Contact Sensor v2 EU
- Brand
- Ring
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_SLEEPING_REPORTING
- User icon
- 0x0C07
- Categories
- Sensors
- Product id
- 0x0301
- S2 classes
- S2_UNAUTHENTICATED, S2_AUTHENTICATED
- Device type
- Notification Sensor
- Oem version
- HW: 1 FW: 1.10
- Library type
- SLAVE_ENHANCED_232
- Product line
- Ring Alarm
- Supports nwi
- Yes
- Installer icon
- 0x0C07
- Z wave version
- 7.12.2
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x0346
- Product type id
- 0x0201
- Long description
- Ring Alarm Contact Sensor is a wireless sensor for the Ring Alarm system which provides users the ability to know when a door or window is open or closed. After installing the sensor on a door or window and setting up the sensor in the Ring app, monitor and receive notifications when the door or window opens or closes. The Ring Alarm Base Station is required to enable Contact Sensor features and functions within the Ring app.
- Hardware platform
- EFR32Z
- Short description
- Ring Alarm Contact Sensor is a wireless sensor for the Ring Alarm system which provides users the ability to know when a door or window is open or closed.
- Association groups
- Group Number Maximum Nodes Supported End Point ID Group Name Profile Description 1
- Product identifier
- Contact Sensor v2 EU
- Countries / regions
- European Union
- Supports smart start
- Yes
- Certification number
- ZC12-21040216
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Flag Advanced Size Min Value Max Value Default Value Parameter Values 1
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_CONFIGURATION_V4
- Supported notification types
- Notification Type Event / State Home Security
- From to description 1 70 this parameter is the number of minutes between heartbeats. 2 application retriess number of application level retries attempted for messages either not acked or messages encapsulated via supervision get that did not receive a report. 2 yes 1 0 5 1 from to description 0 5 this parameter is the number of application level retries. 3 application level retry base wait time period the number base seconds used in the calculation for sleeping between retry messages. 2 yes 1 1 96 5 from to description 1 96 this parameter is the number base seconds used in the calculation for sleeping between retry messages. 4 led indicator enable this parameter allows a user, via software, to configure the various led indications on the device. 0 == don't show green 1 == show green after supervision report intrusion (fault) 2 == show green after supervision report both intrusion and intrusion clear 2 yes 1 0 2 1 from to description 0 2 this parameter is used to configure the various led indications on the device. 5 one shot timer writing to this parameter prompts the sensor to send a wakeup notification one time after this parameter's number of seconds. after which it is reset back to 0. 2 yes 2 5 65535 0 from to description 5 65535 this parameter prompts the sensor to send a wakeup notification. 6 supervisory report timeout the number of milliseconds waiting for a supervisory report response to a supervisory get encapsulated command from the sensor before attempting a retry. 2 yes 2 500 5000 1500 from to description 500 5000 this parameter is the number of milliseconds waiting for a supervisory report response to a supervisory get. texts