- Name
- Environmental Sensor
- Brand
- Secure Controls (UK)
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_SLEEPING_REPORTING
- Categories
- Sensors
- Product id
- 0x0003
- Device type
- Multilevel Sensor
- Oem version
- FW: 1.1
- Library type
- SLAVE_ROUTING
- Supports nwi
- Yes
- Z wave version
- 6.51.02
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x0059
- Product type id
- 0x000D
- Long description
- The Environmental Sensor (SES 303) measures temperature and humidity. The sensors are battery-operated devices which transmit information to an associated device in a network. It can support either 1 thermistor (SES 001) or up to 4 external digital temperature sensors (SES 002/003). SES 303 operates on 2x AA batteries, providing a nominal life of 2 years (with on-board sensors operating with the default configuration).
- Hardware platform
- ZM5202
- Short description
- The Environmental Sensor (SES 303) is a temperature and humidity sensor, which also supports four external digital temperature sensors or one external analog temperature sensor.
- Association groups
- Group Number Maximum Nodes Supported End Point ID Description 1
- Product identifier
- SES 303
- Countries / regions
- European Union
- Certification number
- ZC10-15010003
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 3
- Supports explorer frames
- Yes
- From to description 0 255 resolution is in 0.1 %rh 4 humidity reporting interval this parameter is used to configure the time interval based humidity report. controllers may only allow configuring signed values. in order to set values in the range 128…255, the value sent in the application shall be equal to desired value minus 256. for example, to set delta temperature to 130, it may be needed to set a value 130−256=−126. 0 1 0 0 5 from to description 0 255 resolution is in 1 minute 1 delta temperature this parameter is used to configure the delta based temperature report. to configure delta temperature reporting to 2 °c. the value need to configured in device is 2/0.1 = 20. controllers may only allow configuring signed values. in order to set values in the range 128…255, the value sent in the application shall be equal to desired value minus 256. for example, to set delta temperature to 130, it may be needed to set a value 130−256=−126. 0 1 0 0 0 from to description 0 255 resolution is in 0.1 deg c 2 temp reporting intervals this parameter is used to configure the time interval based temperature report. controllers may only allow configuring signed values. in order to set values in the range 128…255, the value sent in the application shall be equal to desired value minus 256. for example, to set delta temperature to 130, it may be needed to set a value 130−256=−126. 0 1 0 0 5 from to description 0 255 resolution is in 1 minute texts
- ID Description Value 2