- Name
- SSP
- Brand
- Secure Controls (UK)
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_ALWAYS_ON
- Categories
- All Lighting Devices, On/Off Switches/Devices
- Product id
- 0x0002
- Device type
- On/Off Power Switch
- Oem version
- 02
- Library type
- SLAVE_ROUTING
- Supports nwi
- Yes
- Z wave version
- 6.51.02
- Frequency plans
- ANZ: 919.80MHz, 921.40MHz
- Manufacturer id
- 0x0059
- Product type id
- 0x000E
- Long description
- The Secure SSP 301 is a switch and repeater that forms part of a Z-Wave Plus™ home automation network. The SSP 301 is a mains powered device with ANZ plug type, that will switch (power On/Off) a connected appliance either by the Z-Wave network or manually by pressing its integrated button. The SSP 301 acts as a repeater in a Z-Wave network by helping messages from other devices reach there destinations.
- Hardware platform
- ZM5202
- Short description
- SSP 301 is mains power device with ANZ plug type, that can switch (power On/Off) the load of 2300 W and it will also acts as repeater in Z-Wave network, to help other devices to reach there destination.
- Association groups
- Group Number Maximum Nodes Supported End Point ID Description 1
- Product identifier
- SSP 301 ANZ
- Countries / regions
- Australia
- Certification number
- ZC10-15020010
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 1
- Supports explorer frames
- Yes
- From to 0 1 2 time interval based switch status reporting this configuration enable the switch status reporting based on the time interval configured. note: controllers may only allow configuring signed values. in order to set values in the range 32768 …65520, the value sent in the application shall be equal to desired value minus 65520. for example, to set time interval to 36000 seconds it may be needed to set a value 36000−65536=−29536. 0 2 0 0 0 from to 0 65520 3 relay and led configuration this configuration is used to change the relay led status when relay is open/close and also enable to whether to retain the last relay status over power cycle. 0 relay status will not be retain over power cycle, and relay status led will lit when relay on and relay status led will off when relay off. 1 relay status will be retain over power cycle, and relay status led will lit when relay on and relay status led will off when relay off. 2 relay status will not be retain over power cycle, and relay status led will off when relay on and relay status led will lit when relay off. 3 relay status will be retain over power cycle, and relay status led will off when relay on and relay status led will lit when relay off. 0 1 0 0 0 from to 0 3 texts
- ID Description Value 1