- Name
- Aeotec Radiator Thermost
- Brand
- Aeotec
- Features
- Feature Values Battery Quantity
- Is flirs
- Yes
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_SLEEPING_LISTENING
- User icon
- 0x1200
- Categories
- Thermostats
- Product id
- 0x0015
- S2 classes
- S2_UNAUTHENTICATED
- Device type
- Thermostat - HVAC
- Oem version
- HW: 49 FW: 0.16:00.10
- Library type
- SLAVE_ENHANCED_232
- Product line
- Radiator Thermostat
- Supports nwi
- Yes
- Installer icon
- 0x1200
- Z wave version
- 6.71.01
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x0371
- Product type id
- 0x0002
- Long description
- With the Aeotec Radiator Thermostat you get many functions. It regulates the room temperature to your comfort. For the best use it is equipped with FLiRS (Frequently Listening Receiver Slave) and reacts immediately to incoming commands of the Z-Wave controller. Furthermore the device is able to be connected to an external Z-Wave temperature sensor. Because of that the thermostat refers to the temperature of the external sensor, which can be placed in the middle of the room. The display of the thermostat has a background light and has a big LCD screen. Besides you can also lock the local buttons as a child protection. The multicolor LED of the central button allows a intuitive usability because the User is invited to follow the instruction based on the blinking LED of the middle butto. The TRV can either be used as heating thermostat or as a actuator depending on the configuration of the device. The measured temperature or the position of the actuator of the thermostat are transfered to the Z-Wave gateway.
- Hardware platform
- ZM5202
- Short description
- Smart Radiator Thermostat for the installation on heating panels. Measures the room temperature and regulates it to the desired temperature.
- Product identifier
- 4251295701387
- Countries / regions
- United Arab Emirates
- Certification number
- ZC10-19086734
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Format Size Min Value Max Value Default Value Parameter Values 1
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_SWITCH_MULTILEVEL
- Supported multilevel sensors
- Multilevel Sensor Type Air temperature
- Supported notification types
- Notification Type Event / State Power Management
- Value white thermostat hvac systems supported value heat only thermostat modes value energy save heat association groups
- Group Number Maximum Nodes Supported End Point ID Group Name Description 1
- From to description 1 1 lcd content inverted 0 0 normal orientation 3 backlight 1 1 0 1 1 from to description 1 1 backlight enabled 0 0 backlight disabled 5 measured temperature report 1 1 0 50 0 from to description 1 50 reporting delta in 1/10 celcius 0 0 reporting disabled 4 battery report 1 1 0 1 1 from to description 0 0 battery reporting disabled 1 1 battery reporting enabled 6 valve percentage report 1 1 0 100 0 from to description 1 100 reporting delta in percent 0 0 reporting disabled 7 window open detection 1 1 0 3 0 from to description 1 3 sensitivity level 0 0 detection disabled 8 measured temperature offset 1 1 128 50 0 from to description 128 128 temperature is supplied externaly 50 50 offset in 1/10 celcius texts
- ID Description Value 1