- Name
- EU Z-WAVE DOOR WINDOW SENSOR
- Brand
- Ecolink Intelligent Technology
- Features
- Feature Values Sensors
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_SLEEPING_REPORTING
- User icon
- 0x0C00
- Categories
- Sensors
- Product id
- 0x0002
- Device type
- Notification Sensor
- Oem version
- HW: 2 FW: 10.01
- Library type
- SLAVE_ENHANCED
- Supports nwi
- Yes
- Installer icon
- 0x0C07
- Z wave version
- 6.51.06
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x014A
- Product type id
- 0x0004
- Long description
- Includes Brown & White covers Sleek design virtually disappears Easy-to-open case requires no special tools Case tamper protection Ideal for double-hung window Up to 3 year battery life on 1 CR123A lithium battery Uses rare earth magnet for up to 5/8th inch gap detection Includes white and brown cases
- Hardware platform
- ZM5202
- Short description
- Ecolink Z-Wave Door/Window Sensor -Z-Wave Plus certified -Frequency 868.4MHz (CEPT regions) -Range up to 100 feet -Battery life up to 3 years with 50 openings/closing per day -CR123A Lithium battery -Input on the sensor for non-powered external contact -BOTH brown and white cases included in each box
- Product identifier
- H114101
- Countries / regions
- European Union
- Certification number
- ZC10-18056109
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 1
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_POWERLEVEL
- Controlled command classes
- Identifier Name Key Version COMMAND_CLASS_BASIC
- Supported multilevel sensors
- Multilevel Sensor Type General purpose
- Supported notification types
- Notification Type Event / State Home Security
- Value open/closed (binary) supported notification types value home security battery quantity value 1 battery type value cr123 a association groups
- Group Number Maximum Nodes Supported End Point ID Description 1
- From to description 1 0 0x00 off, 0x ff on 2 sending sensor binary report parameter 2 configures the sensor to either to send or not to send sensor binary report commands to association group 1 when the sensor is faulted and restored. if the controller is fully compatible with the notification command class thereby making the sensor binary reports redundant, the controller can disable the sensor binary report commands completely. 0 1 0 0 0 from to description 1 0 0x00 off, 0x ff on texts
- ID Description Value 6