- Name
- Mold Detector
- Brand
- Popp & Co.
- Features
- Feature Values Battery Quantity
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_SLEEPING_REPORTING
- User icon
- 0x0C10
- Categories
- Sensors, HVAC
- Product id
- 0x0014
- S2 classes
- S2_UNAUTHENTICATED
- Device type
- Notification Sensor
- Oem version
- HW: 1 FW: 1.00
- Library type
- SLAVE_ENHANCED_232
- Supports nwi
- Yes
- Installer icon
- 0x0C00
- Z wave version
- 6.81.01
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x0154
- Product type id
- 0x0004
- Long description
- This device measures the three air quality parameters temperature, humidity and dew point an reports them to a central controller. Beside this, the device can directly control groups of other Z-Wave devices on over- and undershooting a set temperature and/or humidity parameter. This can be used to establish control loops for temperature and humidity. The device wakes up every 4 minutes to measure the values and it will send unsolicited reports when values change. Additionally, the device will report all values on request. The mold detector is actively monitoring the danger of mold in a room based on the temperature and humidity and will issue alarm warnings when critical air conditions met. Wireless Alarm and red and a green blinking LED will indicate a mold condition. This local LED warning function is also available when the device is not included in any Z-Wave network and works stand alone.
- Hardware platform
- ZM5101
- Short description
- The device measures environmental parameters and will warn when the air in the room will allow growth of mold.
- Product identifier
- POPE700878
- Countries / regions
- European Union
- Supports smart start
- Yes
- Certification number
- ZC10-19026384
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 6
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
- Controlled command classes
- Identifier Name Key Version COMMAND_CLASS_BASIC
- Supported multilevel sensors
- Multilevel Sensor Type Moisture
- Supported notification types
- Notification Type Event / State Water Alarm
- Value 1 battery type value 1/aa color value white firmware updatable value updatable by consumer by rf sensors value moisture supported notification types value water alarm association groups
- Group Number Maximum Nodes Supported End Point ID Description 2
- From to description 200 1000 1/10 degree 0 0 disabled 7 humidity upper watermark value this parameter defines a relative humidity. if the measured relative humidity surpasses this watermark a basic command is sent into association group 4 0 1 0 0 0 from to description 0 0 disabled 10 100 % 4 periodic reports this parameter defines the time interval to send an unsolicited report. if the value is set to 0, there will be no periodic reports sent to the controller. however, reports on temperature/humidity changes, managed by configuration parameters 1 and 2, may still be active. 0 2 0 0 43200 from to description 0 0 disabled 900 1 seconds 8 humidity lower watermark value this parameter defines a relative humidity. if the measured temperature drops below this relative humidity a basic command is sent into association group 5 0 1 0 0 0 from to description 0 0 disabled 1 90 % 9 low temperature trigger basic set command value this defines what basic command shall be sent out into association group 3 0 1 0 0 1 from to description 0 1 value 5 temperature upper watermark value this parameter defines a temperature. if the measured temperature surpasses this watermark a basic command is sent into association group 2. 0 2 0 0 0 from to description 0 0 disabled 1 1000 1/10 degree 10 high temperature trigger basic set command value this defines what basic command shall be sent out into association group 2 0 1 0 0 0 from to description 0 1 value 11 low humidity trigger basic set command value this defines what basic command shall be sent out into association group 5 0 1 0 0 1 from to description 0 1 value texts