- Name
- 10 Year Smoke Detector and Siren
- Brand
- Popp
- Features
- Feature Values Outdoor Use
- Is flirs
- Yes
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_SLEEPING_LISTENING
- User icon
- 0x0C01
- Categories
- Sensors, Security Add-Ons
- Product id
- 0x0004
- Device type
- Notification Sensor
- Oem version
- HW: 1 FW: 1.00
- Library type
- SLAVE_ENHANCED_232
- Supports nwi
- Yes
- Installer icon
- 0x0C01
- Z wave version
- 6.51.06
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x0154
- Product type id
- 0x0004
- Long description
- This products consists of a standard high-quality photo electric Smoke detector with a pluggable Z-Wave wireless interface module. The Smoke detector will also work as a stand alone product and is certified as '10 year Smoke Detector' The smoke chamber of the detector has a stainless steel reel with antistatic plastic chamber. A button allows on-device test of smoke chamber, electronics and battery. The device also offers a built-in self test and an electronic smoke chamber test to avoid the use of test aerosol. A low battery warning will last for 30 days but full function of the detector is guaranteed during this time. The Z-Wave module allows to report the smoke and low battery alarm wirelessly to a central controller. The detector can also be used as a wireless siren for alarm system or other applications.
- Hardware platform
- ZM5202
- Short description
- EN 14604 certified 10 Year Smoke Detector with built in Z-Wave controllable siren function
- Product identifier
- Ei600ZW
- Countries / regions
- European Union
- Certification number
- ZC10-16125370
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 3
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_POWERLEVEL
- Controlled command classes
- Identifier Name Key Version COMMAND_CLASS_BASIC
- Value white battery type value cr2 battery quantity value 1 association groups
- Group Number Maximum Nodes Supported End Point ID Description 2
- From to description 255 255 basic set command 0 99 basic set command 4 value of off command this value is sent as basic set to association group 3 when an smoke alarm is cleared. if 255 can not be entered in your gateway use 1. 0 1 0 0 0 from to description 255 255 basic set command 0 99 basic set command 1 siren alarm sequence interval the additional siren is creating a different acoustic signal differentiate from the smoke alarm. this sound is partly on and partly off. this parameter defines the total length of the interval in seconds. 0 1 0 0 10 from to description 6 127 seconds 2 siren alarm tone length the additional siren is creating a different acoustic signal differentiate from the smoke alarm. this sound is partly on and partly off. this parameter defines the total length of the sound versus silence within this interval. please make sure this value is always smaller (shorter time) than parameter 1 that defines the whole sequence. 0 1 0 0 8 from to description 1 99 seconds texts
- ID Description Value 2