- Name
- Z-Wave Plus thermostat
- Brand
- Radio Thermostat Company of America
- Features
- Feature Values Battery Quantity
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_ALWAYS_ON
- User icon
- 0x1200
- Categories
- Thermostats
- Product id
- 0x0024
- S2 classes
- S2_UNAUTHENTICATED, S2_AUTHENTICATED
- Device type
- Thermostat - HVAC
- Oem version
- HW: 255 FW: 12.06
- Library type
- SLAVE_ENHANCED_232
- Supports nwi
- Yes
- Installer icon
- 0x1200
- Z wave version
- 6.81.03
- Frequency plans
- US: 916.00MHz, 908.40MHz
- Manufacturer id
- 0x0098
- Product type id
- 0xC801
- Long description
- Z-Wave Plus thermostat for the Home Security and Home Automation markets. The feature-packed technology from Radio Thermostat includes a dynamic power supply to maximize battery lifetime and Z-Wave Plus mesh network connectivity.
- Hardware platform
- ZM5202
- Short description
- Z-Wave Plus thermostat for the Home Security and Home Automation markets.
- Product identifier
- CT200-G1
- Countries / regions
- United States of America
- Supports smart start
- Yes
- Certification number
- ZC10-19086714
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 4
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
- Supported multilevel sensors
- Multilevel Sensor Type Air temperature
- Value 4 battery type value aa alkaline thermostat modes value heat cool auto auxiliary/emergency heat furnace thermostat power source value battery mains powered (120 v/240 v) external transformer sensors value air temperature humidity thermostat hvac systems supported value universal heat only single stage multi stage heat pump dual fuel association groups
- Group Number Maximum Nodes Supported End Point ID Description 1
- From to description 1 2 0x01 c wire 0x02 batteries 5 humidity reporting threshold the humidity reporting threshold parameter specifies the threshold change in the relative humidity as detected by the thermostat to trigger an unsolicited report when association reporting is enabled. 0 1 0 0 2 from to description 0 3 0x00 disabled reporting 0x01 3% relative humidity 0x02 5% relative humidity (default) 0x03 10% relative humidity 9 thermostat recovery mode the thermostat recovery mode parameter specifies the hvac recovery mode type. 0 1 0 0 2 from to description 0 1 0x01 fast mode 0x02 economy mode (default) 10 temperature reporting filter the temperature reporting filter parameter specifes the upper and lower bounds of the ambient temperature reporting. 0 4 0 0 0 from to description 0 1 upper bound temperature scale 0 124 upper bound temperature filter 0 1 lower bound temperature scale 0 124 lower bound temperature filter 11 fan timer this configuration is used to activate the fan with an automatic shut off timer. 0 1 0 0 0 from to description 0 60 0x00 always on (default) 0x0 f 15 minutes 0x1 e 30 minutes 0x3 c 60 minutes 1 temperature reporting threshold the temperature reporting threshold parameter specifies the threshold change in the ambient air temperature as detected by the thermostat to generate an usolicited report when association reporting is enabled. 0 1 0 0 2 from to description 0 4 0x00 disable reporting 0x01 0.5 degrees fahrenheit 0x02 1.0 degrees fahrenheit (default) 0x03 1.5 degrees fahrenheit 0x04 2.0 degrees fahrenheit 3 utility lock the utility lock parameter enables or disables the utility lock. if the utility lock is enabled, the thermostat setpoint cannot be modified by the user on the thermostat physical user interface. 0 1 0 0 0 from to description 0 3 0x00 disabled lock (default) 0x01 n/a 0x02 n/a 0x03 enabled lock 2 hvac settings the hvac settings parameter contains a read only description of the hvac settings of the thermostat. 0 4 0 0 0 from to description 0 255 a terminal, heat pump stages 0 255 o/b terminal, cooling stages 0 255 heating fuel, heat/aux stages 0 255 cooling type, heating type 7 thermostat swing the thermostat swing temperature parameter specifies the swing temperature on the thermostat. 0 1 0 0 2 from to description 0 8 0x00 not supported 0x01 0.5 degrees fahrenheit 0x02 1.0 degrees fahrenheit (default) 0x03 1.5 degrees fahrenheit 0x04 2.0 degrees fahrenheit 0x05 2.5 degrees fahrenheit 0x06 3.0 degrees fahrenheit 0x07 3.5 degrees fahrenheit 0x08 4.0 degrees fahrenheit 6 auxiliary heat the auxiliary heat parameter enables or disables thermostat mode called auxiliary heating in the thermostat while the thermostat mode is heat. 0 1 0 0 0 from to description 0 1 0x00 disabled auxiliary heat (default) 0x01 enabled auxiliary heat texts