- Name
- CT32
- Brand
- Radio Thermostat Company of America
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_ALWAYS_ON
- Categories
- Thermostats
- Product id
- 0x0100
- Device type
- Thermostat - HVAC
- Oem version
- HW: 250
- Library type
- SLAVE_ENHANCED_232
- Supports nwi
- Yes
- Z wave version
- 6.51.02
- Frequency plans
- US: 916.00MHz, 908.40MHz
- Manufacturer id
- 0x0098
- Product type id
- 0x2002
- Long description
- The Z-Wave enabled CT32 thermostat is a compact, easy-to-use thermostat that is packed with functionality. The CT32 has a responsive touchscreen interface, easy-to-read backlight display, and 7-day programmability. It features a system lock to avoid unintentional changes for maximum efficiency, a filter change indicator to keep your HVAC system running efficiently, wide temperature operation range, and room temperature calibration for precise control.
- Hardware platform
- ZM5202
- Short description
- The Z-Wave enabled CT32 thermostat is a touchscreen thermostat that is packed with functionality.
- Association groups
- Group Number Maximum Nodes Supported End Point ID Description 1
- Product identifier
- CT32
- Countries / regions
- United States of America
- Certification number
- ZC10-15060004
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 10
- Supports explorer frames
- Yes
- From to description 0 31868 byte 1: 0 124 f (lower bound), byte 2: 0 124 f (upper bound) 1 temperature reporting threshold the temperature reporting threshold configuration set command sets the reporting threshold for changes in the ambient temperature as detected by the thermostat. 0 1 0 0 2 from to 0 4 9 thermostat recovery mode the thermostat recovery mode configuration command sets the hvac recovery mode type. the recovery mode determines when additional hvac stages are turned off as the ambient temperature returns to the target temperature. 0 1 0 0 2 from to description 1 2 1 = fast, 2 = economy 2 hvac settings the hvac settings configuration report command returns the current hvac configuration. the hvac settings must be fixed before the thermostat is joined to the z wave network. 0 4 0 0 0 from to description 1 2147483647 byte 1: normal (1) or heat pump (2). byte 2, bits 7 4: gas (1) or electric (2). byte 2, bits 3 0: # of auxiliary stages. byte 3: # of heat pump stages. byte 4: # of cool stages. 11 simple ui mode enables or disables simple ui mode on thermostat via radio bus read/set ui command. 0 1 0 0 1 from to description 0 1 0 = normal mode, 1 = simple mode 8 thermostat differential temperature the thermostat differential temperature configuration command sets the differential temperature for multi stage hvac systems. 0 2 0 0 4 from to description 2 6 the thermostat differential temperature is in units of 0.5 degrees fahrenheit. 0 1 0x00 (heat) or cool (0x01) 3 utility lock the utility lock configuration set command enables or disables the utility lock. if the utility lock is enabled, the setpoint cannot be modified directly via the thermostat screen. 0 1 0 0 0 from to description 0 255 0 = disabled, 1 255 = enabled 4 c wire/battery the c wire / battery status configuration report command returns the status of the thermostat power source. the power state is fixed when the thermostat joins the network. 0 1 0 0 0 from to description 1 2 1=c wire, 2=battery 5 humidity reporting threshold the humidity threshold configuration set command sets the reporting threshold for changes in the relative humidity as detected by the thermostat. 0 1 0 0 5 from to description 0 3 0 = disabled, 1 = 3% rh, 2 = 5% rh, 3 = 10% rh 6 auxiliary/emergency mode the auxiliary/emergency configuration command enables or disables auxiliary / emergency heating in the thermostat. 0 1 0 0 0 from to description 0 1 0 = disabled, 1 = enabled 7 thermostat swing temperature the thermostat swing temperature configuration command sets swing temperature on the thermostat. 0 1 0 0 2 from to description 1 8 1 = 0.5ºf, 2 = 1.0ºf, 3 = 1.5ºf, 4 = 2.0ºf, 5 = 2.5ºf, 6 = 3.0ºf, 7 = 3.5ºf, 8 = 4.0ºf texts