- Name
- REM50Z
- Brand
- RCS
- Features
- Feature Values Color
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_ALWAYS_ON
- User icon
- 0x0DFF
- Categories
- Sensors, HVAC
- Product id
- 0x3530
- Device type
- Notification Sensor
- Oem version
- HW: 1 FW: 6.61:01.00
- Library type
- SLAVE_ROUTING
- Supports nwi
- Yes
- Installer icon
- 0x0DFF
- Z wave version
- 6.61.00
- Frequency plans
- US: 916.00MHz, 908.40MHz
- Manufacturer id
- 0x0010
- Product type id
- 0x454D
- Long description
- The REM50Z (Remote Equipment Monitor) Quad Channel Remote Temperature Sensor is a wall mountable Z-Wave remote temperature sensor for use with all Z-Wave systems. This sensor is ideal for remotely monitoring up to 4 operating temperatures on HVAC systems: Supply, Return, and Refrigeration In/Out Line Temps. Additionally, the REM50 has a single channel contact closure / voltage detection circuit that can be used to monitor and report Condensate Pan fill level of the HVAC system. Features • Z-Wave 500 Series Radio • Supports Z-Wave Plus • Quad Temp Sensor Circuits: +/- 1 degree F, Range: -40F to 120F o Designed for 10k Thermistor temp sensors, not included • 1 Contact Closure / Voltage Detection Circuit o Designed to detect Float Switch closure, not included • 6 Status LEDs • Designed for interior use in mechanical room, attic or crawlspace • Compatible with RCS Z-Wave Thermostats • Compatible with all Z-Wave systems • Wall Mountable • Small, Thin, Lightweight • Grey, Paintable Dimensions • 5.10” X 2.25” X 0.9” Power • 16 – 28 VAC • 12 – 24 VDC
- Hardware platform
- ZM5202
- Short description
- The REM50Z is a wall mountable sensor for remotely monitoring up to 4 temperatures and has a voltage detection circuit that can be used to monitor condensate pan fill level of an HVAC system.
- Product identifier
- REM50Z
- Countries / regions
- United States of America
- Certification number
- ZC10-18076173
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 1
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_SENSOR_MULTILEVEL_V5
- Supported multilevel sensors
- Multilevel Sensor Type Air temperature
- Supported notification types
- Notification Type Event / State Water Alarm
- Value gray sensors value air temperature voltage supported notification types value water alarm firmware updatable value updatable by consumer by rf association groups
- Group Number Maximum Nodes Supported End Point ID Description 1
- From to description 7 7 degrees 2 rs2 sensor cal add or subtract an offset for the s2 temperature sensor. 0 1 0 0 0 3 rs3 sensor cal add or subtract an offset for the s3 temperature sensor. 0 1 0 0 0 from to description 7 7 degrees 9 rs1 lifeline periodic temperature send interval how many minutes between periodic temperature reports. 0 1 0 0 120 from to description 1 120 minutes 4 rs4 sensor cal add or subtract an offset for the s4 temperature sensor. 0 1 0 0 0 from to description 7 7 degrees 17 rs1 group2 periodic temperature send interval how many minutes between periodic temperature reports to association group 2. 0 1 0 0 0 from to description 0 120 minutes 23 rs2 time constant filter time constant. larger number gives a slower temperature response. 0 1 0 0 10 from to description 1 60 seconds 24 rs3 time constant filter time constant. larger number gives a slower temperature response. 0 1 0 0 10 from to description 1 60 seconds 10 rs2 lifeline periodic temperature send interval how many minutes between periodic temperature reports. 0 1 0 0 120 from to description 1 120 minutes 11 rs3 lifeline periodic temperature send interval how many minutes between periodic temperature reports. 0 1 0 0 120 from to description 1 120 minutes 25 rs4 time constant filter time constant. larger number gives a slower temperature response. 0 1 0 0 10 from to description 1 60 seconds texts
- ID Description Value 1