- Name
- Secure Smart Plug 302
- Brand
- Secure Controls
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_ALWAYS_ON
- Categories
- Energy Meters, All Lighting Devices, On/Off Switches/Devices
- Product id
- 0x0001
- Device type
- On/Off Power Switch
- Oem version
- 01
- Library type
- SLAVE_ROUTING
- Supports nwi
- Yes
- Z wave version
- 6.51.02
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x0059
- Product type id
- 0x0011
- Long description
- SSP 302 EU variant is a mains-powered, plug-in device that supports energy monitoring. It is suitable for switching loads up to 3.6KW at 230V AC. It can measure voltage, current, power, energy etc. The SSP 302 acts as a repeater in a Z-Wave network by helping messages from other devices reach there destinations, without losing a plug socket.
- Hardware platform
- ZM5202
- Short description
- SSP 302 EU variant is a mains-powered, plug-in device that supports energy monitoring. It is suitable for switching loads up to 3.6KW at 230V AC. It can measure voltage, current, power, energy etc.
- Association groups
- Group Number Maximum Nodes Supported End Point ID Description 1
- Product identifier
- SSP 302 UE
- Countries / regions
- European Union
- Certification number
- ZC10-15020014
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 11
- Supports explorer frames
- Yes
- Controlled command classes
- Identifier Name Key Version COMMAND_CLASS_TIME
- From to 0 65520 8 switch status time interval based this configuration parameter will be used to set the time interval base reporting of switch status in 1 second resolution. 0 2 0 0 0 from to 0 65520 9 voltage time interval based this configuration parameter will be used to set the time interval base reporting of voltage in 1 second resolution. 0 2 0 0 0 from to 0 65520 3 current delta based configuration this configuration parameter will be used to enable/disable the delta base curenrt reporting. resolution of this parameter is 10 m a. if user wants to set 1 a delta then it should be 1/0.01 = 100. 0 1 0 0 0 from to 0 1500 4 power factor delta based configuration this configuration parameter will be used to enable/disable the delta base power factor reporting in 0.1% resolution. if user wants to set power factor 10% = 10/0.1 = 100 0 2 0 0 0 from to 0 1000 0 0 1 switch status delta based configuration this configuration parameter will be used to enable/disable the delta base switch status reporting. 0 1 0 0 1 from to 0 1 2 voltage delta based configuration this configuration parameter will be used to enable/disable the delta base voltage reporting. resolution of this parameter is 100 m v. if user wants to set 10 v delta then it should be 10/0.1 = 100. 0 2 0 0 0 from to 0 600 7 apparent energy delta based configuration this configuration parameter will be used to enable/disable the delta base apparent energy reporting in 1 vah resolution. 0 2 0 0 0 from to 0 32000 10 current time interval based this configuration parameter will be used to set the time interval base reporting of current in 1 second resolution. 0 2 0 0 0 from to 0 65520 6 active energy delta based configuration this configuration parameter will be used to enable/disable the delta base active energy reporting in 1 wh resolution. 0 2 0 0 0 from to 0 32000 5 active power delta based configuration this configuration parameter will be used to enable/disable the delta base active power reporting in 1 w resolution. 0 2 0 0 0 from to 0 4000 texts