- Name
- Micro Smart Dimmer
- Brand
- Sunricher
- Features
- Feature Values Firmware Updatable
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_ALWAYS_ON
- User icon
- 0x0600
- Categories
- All Lighting Devices, Dimming Lighting Devices
- Product id
- 0xD00C
- S2 classes
- S2_UNAUTHENTICATED
- Device type
- Light Dimmer Switch
- Oem version
- HW: 1 FW: 1.06
- Library type
- SLAVE_ENHANCED_232
- Supports nwi
- Yes
- Installer icon
- 0x0600
- Z wave version
- 6.71.03
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x0330
- Product type id
- 0x0200
- Long description
- The micro smart dimmer is a Z-Wave device designed to work with various types of light sources. It may be connected to two-wire or three-wire configuration so it can operate with or without neutral lead. The dimmer can switch or dim connected light source either through Z-Wave devices or through the wall switch connected directly to it. The smart dimmer is equipped with an algorithm of smart light source detection which makes configuration easier and ensures high compatibility of the device. It may be used as a switch with non-dimmable light sources (in 3-wire connection).
- Hardware platform
- ZM5101
- Short description
- The micro smart dimmer is a Z-Wave device designed to work with various types of light sources. It may be connected to two-wire or three-wire configuration so it can operate with or without neutral lead.
- Product identifier
- SR-ZV9040A-A
- Countries / regions
- European Union
- Certification number
- ZC10-19046456
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 4
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
- Supported notification types
- Notification Type Event / State Power Management
- Supported / controlled meter types
- Meter Type Rate Type Description Electric meter
- Value updatable by consumer by rf supported meter type value electric energy supported notification types value power management system association groups
- Group Number Maximum Nodes Supported End Point ID Description 1
- From to description 0 0 instantly 1 127 1 second (0x01) to 127 seconds (0x7 f) in 1 second resolution. 6 setting maximum brightness value setting maximum brightness value 0 1 0 0 100 from to description 0 100 the maximum brightness value 7 choose mosfet driving type choose mosfet driving type 0 1 0 0 0 from to description 0 0 trailing edge 1 1 leading edge 8 external switch type external switch type 0 1 0 0 0 from to description 0 0 push button switch 1 1 normal on/off switch 2 2 3 way switch 9 enable/disable external switch to be added to and removed from a network enable/disable external switch to be added to and removed from a network (when enables this function, triple press the external switch within 1.5 seconds to be added to or removed from a network) 0 1 0 0 1 from to description 0 0 disable 1 1 enable 10 enable/disable to detect load after re power on enable/disable to detect load after re power on (detect load type, minimum brightness, maximum brightness) note: when the device does not belong to any network, load detection will be enabled every time after re power on. when the device has already been added to a network, load detection will be disabled. 0 1 0 0 0 from to description 0 0 disable 1 1 enable to detect every time after re power on 2 2 enable to detect only after first re power on 11 wiring type wiring type note: this parameter is read only 0 1 0 0 0 from to description 0 0 unknown 1 1 2 wire with no neutral 2 2 3 wire with neutral 5 setting minimum brightness value setting minimum brightness value 0 1 0 0 0 from to description 0 50 the bigger the value is, the higher the load’s minimum brightness is 23 voltage metering automatic report time cycle, unit is second voltage metering automatic report time cycle, unit is second 0 4 0 0 3600 from to description 5 2678400 voltage metering automatic report time cycle, unit is second 24 current metering automatic report time cycle, unit is second current metering automatic report time cycle, unit is second 0 4 0 0 3600 from to description 5 2678400 current metering automatic report time cycle, unit is second 2 saving load state before power failure saving load state before power failure 0 1 0 0 2 from to description 1 1 turn on load 2 2 save load state before power failure 0 0 shutoff load 3 enable/disable to send the basic report enable/disable to send the basic report to the lifeline when the load state changed (when value set as 1, re power on the dimmer, it will send basic report automatically) 0 1 0 0 1 from to description 0 0 disable to send basic report 1 1 enable to send basic report texts