- Name
- Titan Water Valve Actuator
- Brand
- Zooz
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_ALWAYS_ON
- User icon
- 0x1500
- Categories
- Water Valves & Irrigation
- Product id
- 0x0036
- S2 classes
- S2_UNAUTHENTICATED, S2_AUTHENTICATED
- Device type
- Binary Switch
- Oem version
- HW: 3 FW: 3.03
- Library type
- SLAVE_ENHANCED_232
- Product line
- Valve Actuators
- Supports nwi
- Yes
- Installer icon
- 0x1500
- Z wave version
- 7.13.2
- Frequency plans
- US: 916.00MHz, 908.40MHz
- Manufacturer id
- 0x027A
- Product type id
- 0x0101
- Long description
- PRODUCT HIGHLIGHTS: Automatic shut-off actuator for your main water valve Connect it to your Z-Wave™ hub for full smart home control Use it offline with the included leak sensor probe Built-in temperature detection for instant freeze detection Retrofit installation with no tools required Use with 1/2” - 1 1/4” ball valves only (close prior to installation) Indoor & outdoor installation with IP66 rating (avoid direct sunlight) NEW 700 series Z-Wave™ chip for better range and faster control S2 Security and SmartStart for easier inclusion PRODUCT SPECS: Model Number: ZAC36 Z-Wave Signal Frequency: 908.42 MHz Power: 12 V DC (1 A) power supply (included) Temperature Sensor Range: -40° to 257° F Sound Indicator: up to 85 dB Z-Wave Range: Up to 400 feet line of sight (up to 130 feet indoors) Operating Temperature: 14-122° F (-10-50° C) Installation and Use: Indoor & outdoor (IP66) Standby Power Consumption: 0.12 W Full Operation Power Consumption: 8.4 W
- Hardware platform
- ZGM130
- Short description
- The Titan Water Valve Actuator is the ultimate DIY retrofit solution for flood prevention in the event of a water leak. Install on ball valves only.
- Association groups
- Group Number Maximum Nodes Supported End Point ID Group Name Description 2
- Product identifier
- ZAC36
- Countries / regions
- United States of America
- Supports smart start
- Yes
- Certification number
- ZC12-22010332
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 42
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_CONFIGURATION_V4
- Supported multilevel sensors
- Multilevel Sensor Type Air temperature
- Supported notification types
- Notification Type Event / State Heat Alarm
- From to description 0 0 operation disabled 1 0 operation enabled (default) 41 freeze recover value set the freeze alarm cancellation trigger value. default: 36. 2 2 0 511 292 from to description 0 511 degrees 43 association group 5 freeze trigger decide which report is sent to group 5 when the freeze alarm (set in parameter 40) is triggered. 3 1 0 2 0 from to description 2 0 basic set off 0 0 reports to group 5 disabled (default) 1 0 basic set on 44 association group 5 freeze cancel decide which report is sent to group 5 when the freeze alarm is cancelled. 3 1 0 2 0 from to description 2 0 basic set off 1 0 basic set on 0 0 reports to group 5 disabled (default) 49 association group 3 water leak trigger decide which report is sent to group 3 when a leak alarm is triggered (from the connected leak detection probe). values: 3 1 0 2 1 from to description 2 0 basic set off 1 0 basic set on (default) 0 0 reports to group 3 disabled 65 buzzer decide if you'd like to receive sound (beep) feedback when operating the actuator as well as sound alarms for different modes and alarms the actuator goes into when installed. 3 1 0 1 1 from to description 0 0 sound notifications disabled 1 0 sound notifications enabled (default) 66 led brightness level decide how bright you'd like the led indicator to be on your actuator. if you set it to value 0, the led indicator will be disabled. default: 80. 2 1 0 99 80 from to description 0 99 % 50 association group 3 water leak cancel decide which report is sent to group 3 when the leak alarm is cleared (water is no longer detected by the connected probe). 3 1 0 2 0 from to description 2 0 basic set off 1 0 basic set on 2 0 basic set off 0 0 reports to group 3 disabled (default) 2 0 basic set off 51 water leak detection valve control decide if you want to allow the valve actuator to open and close during a leak alarm event. if the actuator is disabled, it won't react to z wave or manual triggers to open or close until the leak alarm is cleared. 3 1 0 1 1 from to description 0 0 operation disabled 1 0 operation enabled (default) 17 water valve command and reporting behavior decide which z wave commands and reports you'd like to use to display when the device is open or closed (or to open / close the device). default value: 1. 3 1 0 1 1 from to description 0 0 reports on when the valve is open (opens the valve when an "on" report is sent from the hub), reports off when the valve is closed (closes the valve when an "off" report is sent from the hub) 1 0 reports off when the valve is open (opens the valve when an "off" report is sent from the hub), reports on when the valve is closed (closes the valve when an "on" report is sent from the hub) 67 z wave button lock protection enable z wave button lock protection if you'd like to prevent the z wave button from being locked accidentally. 3 1 0 1 0 from to description 0 0 z wave button lock disabled (default) 1 0 z wave button lock enabled texts