- Name
- Z-WAVE PLUS ON / OFF LIGHT SWITCH
- Brand
- Zooz
- Features
- Feature Values Color
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_ALWAYS_ON
- User icon
- 0x0704
- Categories
- All Lighting Devices, On/Off Switches/Devices
- Product id
- 0xAA01
- S2 classes
- S2_UNAUTHENTICATED
- Device type
- On/Off Power Switch
- Oem version
- HW: 1 FW: 1.00
- Library type
- SLAVE_ENHANCED_232
- Product line
- A
- Supports nwi
- Yes
- Installer icon
- 0x0700
- Z wave version
- 6.81.03
- Frequency plans
- US: 916.00MHz, 908.40MHz
- Manufacturer id
- 0x027A
- Product type id
- 0xAA00
- Long description
- PRODUCT HIGHLIGHTS: - Reliable on/off control for incandescent and LED lights - Unique Direct 3-Way Solution: no add-on switch needed (Neutral wire required) - Scene control (double tap as trigger) - Instant status reports - Advanced settings (built-in timer, LED indicator mode, paddle control, and more) PRODUCT SPECS: - Z-Wave Frequency: 908.42 MHz (US) - Power: 120 VAC, 60 Hz - Maximum Loads: 960W Incandescent, 150W LED and CFL bulbs, 1800W (15A) Resistive - Z-Wave Range: Up to 100 feet line of sight between the Wireless - Controller and the closest Z-Wave receiver module - Operating Temperature: 32-104° F (0-40° C) - Installation: Indoor use only
- Hardware platform
- ZM5202
- Short description
- Use this switch as direct replacement for your single pole or 3-way light switches to gain instant Z-Wave control.
- Product identifier
- ZEN21 VER 3.0
- Countries / regions
- United States of America
- Certification number
- ZC10-19096759
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 4
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
- Controlled command classes
- Identifier Name Key Version COMMAND_CLASS_BASIC_V2
- Value white electric load type value incandescent fluorescent led firmware updatable value updatable by consumer by rf neutral wire required switch load capacity watts value 960 z wave scene type value central scene association groups
- Group Number Maximum Nodes Supported End Point ID Group Name Description 2
- From to description 1 65535 minutes 9 enable/disable scene control enable or disable scene control functionality for quick double tap triggers. 1 1 0 1 0 from to description 0 1 0 – scene control disabled (default). 1 – scene control enabled. 5 enable / disable auto turn off timer use this parameter to enable or disable the auto turn on timer function. 1 1 0 1 0 from to description 0 1 0 – timer disabled (default); 1 – timer enabled. 6 set auto turn on timer use this parameter to set the time after which you want the switch to automatically turn on once it has been turned off. the number entered as value corresponds to the number of minutes. 1 4 1 65535 60 from to description 1 65535 minutes 8 on off status after power failure set the on off status for the switch after power failure. 1 1 0 2 2 from to description 0 0 0 – forced to off (regardless of state prior to power outage) 1 1 forced to on 2 2 remembers and restores on/off status aer power failure (default) 10 enable/disable paddle control enable or disable local on/off control. if enabled, you’ll only be able to control the connected light via z wave. scenes and other functionality will still be available through paddles. 1 1 0 1 1 from to description 0 1 0 – local control disabled. 1 – local control enabled (default). 1 paddle control choose if you want the upper paddle to turn the light on or turn the light off when tapped. 1 1 0 2 0 from to description 0 2 0 – upper paddle turns the light on, lower paddle turns the light off (default); 1 – upper paddle turns the light off, lower paddle turns the light on; 2 – any paddle will turn light on / off depending on the status. 2 led indicator control choose if you want the led indicator to turn on when the switch (light) is on or off, or if you want it to remain on or off at all times. 1 1 0 3 0 from to description 0 0 led indicator is on when switch is off, led indicator is off when switch is on (default) 1 1 led indicator is on when switch is on, led indicator is off when switch is off 2 2 led indicator is always off 3 3 led indicator is always on 3 enable / disable auto turn off timer use this parameter to enable or disable the auto turn off timer function. 1 1 0 1 0 from to description 0 1 0 – timer disabled (default); 1 – timer enabled. texts