- Name
- 700 Toggle Switch
- Brand
- Zooz
- Features
- Feature Values Neutral Wire Required
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_ALWAYS_ON
- User icon
- 0x0704
- Categories
- All Lighting Devices, On/Off Switches/Devices
- Product id
- 0xA003
- S2 classes
- S2_UNAUTHENTICATED, S2_AUTHENTICATED
- Device type
- Binary Switch
- Oem version
- HW: 1 FW: 1.00
- Library type
- SLAVE_ENHANCED_232
- Product line
- Line A
- Supports nwi
- Yes
- Installer icon
- 0x0700
- Z wave version
- 7.13.6
- Frequency plans
- US: 916.00MHz, 908.40MHz
- Manufacturer id
- 0x027A
- Product type id
- 0x7000
- Long description
- FEATURES: - Manual or Z-Wave on/off control with instant status updates - NEW: 700 series Z-Wave chip for better range and faster control - Simple Direct 3-Way: connect with existing on/off switches in 3-way, 4-way, and 5-way set-ups, no add-on needed - Scene control: trigger actions with multi-tap (select hubs only) - Smart bulb mode: disable relay and control the light via Z-Wave - Remembers and restores on/off status after power failure - NEW: discreet LED indicator for easy set-up and troubleshooting - Works with LED and incandescent bulbs (don’t use with tubes)
- Hardware platform
- ZGM130
- Short description
- Toggle Style S2 On/Off Switch with Direct 3-Way / 4-Way Solution.
- Product identifier
- ZEN73
- Countries / regions
- United States of America
- Supports smart start
- Yes
- Certification number
- ZC12-21050228
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 2
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_CONFIGURATION_V4
- Value white electric load type value incandescent led firmware updatable value updatable by consumer by rf switch load capacity current value 8 switch load capacity watts value 150 z wave scene type value central scene association groups
- Group Number Maximum Nodes Supported End Point ID Group Name Description 1
- From to description 0 0 led indicator is on when switch is off, led indicator is off when switch is on (default) 1 1 led indicator is on when switch is on, led indicator is off when switch is off 2 2 led indicator is always off 3 3 led indicator is always on 10 enable/disable scene control enable or disable scene control functionality for quick double tap triggers. 2 1 0 1 0 from to description 0 0 scene control disabled (default) 1 1 scene control enabled 1 on/off toggle orientation choose if you want to turn the light on or turn the light off when you toggle up the switch. 2 1 0 2 0 from to description 0 0 toggle up turns the light on, toggle down turns it off (default) 1 1 toggle up turns the light off, toggle down turns it on 2 2 toggle any direction to turn the light on/off (change state) 3 auto turn off timer use this parameter to enable or disable the auto turn off timer function (the time after which you want the switch to automatically turn off once it has been turned on). 2 4 0 65535 0 from to description 0 0 timer disabled 1 65535 minutes 5 auto turn on timer use this parameter to enable or disable the auto turn on timer function (the time after which you want the switch to automatically turn on once it has been turned off). 2 4 0 65535 0 from to description 0 0 timer disabled 1 65535 minutes 8 on off status after power failure set the on off status for the switch after power failure. 2 1 0 2 2 from to description 0 0 forced to off (regardless of state prior to power outage 1 1 forced to on (regardless of state prior to power outage) 2 2 remembers and restores on/off status after power failure (default) texts