- Name
- In-wall switch
- Brand
- Good Way Technology, Co., Ltd
- Features
- Feature Values Firmware Updatable
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_ALWAYS_ON
- User icon
- 0x0700
- Categories
- Energy Meters, All Lighting Devices, On/Off Switches/Devices
- Product id
- 0x0015
- S2 classes
- S2_UNAUTHENTICATED, S2_AUTHENTICATED
- Device type
- Power Strip
- Oem version
- HW: 1 FW: 2.05
- Library type
- SLAVE_ENHANCED_232
- Supports nwi
- Yes
- Installer icon
- 0x0702
- Z wave version
- 6.81.00
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x0068
- Product type id
- 0x0003
- Long description
- This In-wall Power Monitor Switch is a transceiver which is a Z-Wave enabled device and is fully compatible with any Z-Wave enabled network. Mini-sized design makes it easy to place the In-wall Power Monitor Switch into the wall box and fit in the house decoration.
- Hardware platform
- ZM5101
- Short description
- This In-wall Power Monitor Switch is a transceiver which is a Z-Wave enabled device and is fully compatible with any Z-Wave enabled network.
- Product identifier
- TD13010
- Countries / regions
- European Union
- Supports smart start
- Yes
- Certification number
- ZC10-18066136
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 3
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
- Supported notification types
- Notification Type Event / State Power Management
- Supported / controlled meter types
- Meter Type Rate Type Description Electric meter
- Value updatable by manufacturer supported meter type value electric energy supported notification types value power management switch type value toggle loads controlled value 2 association groups
- Group Number Maximum Nodes Supported End Point ID Description 1
- From to description 0 2 switch type 4 reload power status 0 : device does not memorize its status at power cut. load is disconnected (default) 1 : device memorizes its status at the power cut. load will be set to the status from before power cut. 0 1 0 0 0 from to description 0 1 reload power status 5 power reporting on power change 0 : disabled 1~100 : 1 % ~ 100 %. (default = 10%) 0 1 0 0 10 from to description 0 0 disble 1 100 change rate 6 watts auto report period 0 : disabled 60~32767 seconds. (default = 300 seconds) 0 2 0 0 300 from to description 0 0 disable 60 32767 watts auto report period 7 kwh auto report period 0 : disabled set time interval of reporting kwh (60 ~32767) in seconds. 0 2 0 0 3600 from to description 0 0 disable 60 32767 kwh auto report period 8 d1 automatically turn on 0 : disable (default) 1~32767 : time in second that the o2 will turn on automatically. 0 2 0 0 0 from to description 0 0 disable 1 32767 d1 automatically turn on 9 d2 automatically turn on 0 : disable (default) 1~32767: time in second that the o2 will turn on automatically. 0 2 0 0 0 from to description 0 0 disable 1 32767 d2 automatically turn on 2 d2 automatically turn off 0 : disable (default) 1~32767: time in second that the o2 will turn off automatically. 0 2 0 0 0 from to description 0 0 disable 1 32767 d2 automatically time 1 d1 automatically turn off 0 : disable (default) 1~32767 : time in second that the o2 will turn off automatically. 0 2 0 0 0 from to description 1 32767 d1 automatically time 0 0 disable texts