- Name
- Smart Plug
- Brand
- Hank
- Features
- Feature Values Firmware Updatable
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_ALWAYS_ON
- User icon
- 0x0700
- Categories
- Energy Meters, All Lighting Devices, On/Off Switches/Devices
- Product id
- 0x0005
- Device type
- On/Off Power Switch
- Oem version
- HW: 1 FW: 1.03
- Library type
- SLAVE_ENHANCED_232
- Supports nwi
- Yes
- Installer icon
- 0x0700
- Z wave version
- 6.51.07
- Frequency plans
- US: 916.00MHz, 908.40MHz
- Manufacturer id
- 0x0208
- Product type id
- 0x0101
- Long description
- Smart Plug is a Z-Wave Switch plugin module specifically used to enable Z-Wave command and control (on/off) of any plug-in tool. It can report wattage consumption or kWh energy usage.Smart Plug is also a security Z-Wave device and supports the Over The Air (OTA) feature for the product’s firmware upgrade.
- Hardware platform
- ZM5202
- Short description
- Smart Plug is a Z-Wave Switch plugin module specifically used to enable Z-Wave command and control (on/off) of any plug-in tool. It can report wattage consumption or kWh energy usage.
- Product identifier
- HKZW-SO01
- Countries / regions
- United States of America
- Certification number
- ZC10-16065124
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 151
- Supports explorer frames
- Yes
- Value updatable by consumer by rf switch load capacity current value 15 a association groups
- Group Number Maximum Nodes Supported End Point ID Description 1
- From to description 0 0 the function is disabled 1 65535 the minimum change value in wattage for sending a meter report to the associated device 152 threshold of change in wattage percentage the value here represents minimum change in wattage percent (in terms of percentage) for sending a meter report (for wattage) to the associated device (group lifeline). 0 1 0 0 10 from to description 0 0 the function is disabled. 1 255 the minimum change value in wattage percent for sending a meter report to the associated device 172 intervals of sending meter report (for k wh) the time interval of sending meter report (for k wh) to the associated device (group lifeline). 0 4 0 0 300 from to description 5 2678400 the time for sending a meter report 0 0 the function is disabled. 173 intervals of sending meter report (for voltage). the time interval of sending meter report (for voltage) to the associated device (group lifeline). 0 4 0 0 0 from to description 5 2678400 the time for sending a meter report 0 0 the function is disabled 174 intervals of sending meter report (for current). the time interval of sending meter report (for voltage) to the associated device (group lifeline). 0 4 0 0 0 from to description 0 0 the function is disabled 5 2678400 the time for sending a meter report 24 notification when load status changed smart plug can send notifications to association device (group lifeline) when state of smart plug’s load changed. 0 1 0 0 1 from to description 0 0 the function is disabled. 1 1 send basic report 2 2 send basic report only when load condition is changed not by z wave command, such as short pressing. texts