- Name
- Smart Switch
- Brand
- Hank
- Features
- Feature Values Color
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_ALWAYS_ON
- User icon
- 0x0700
- Categories
- Energy Meters, All Lighting Devices, On/Off Switches/Devices
- Product id
- 0x000D
- Device type
- On/Off Power Switch
- Oem version
- HW: 1 FW: 1.00
- Library type
- SLAVE_ENHANCED_232
- Supports nwi
- Yes
- Installer icon
- 0x0700
- Z wave version
- 6.51.09
- Frequency plans
- US: 916.00MHz, 908.40MHz
- Manufacturer id
- 0x0208
- Product type id
- 0x0101
- Long description
- Smart Switch is a Z-Wave Switch module specifically used to enable Z-Wave command and control (on/off) of any plug-in tool. It can report wattage consumption or kWh energy usage.
- Hardware platform
- ZM5101
- Short description
- Smart Switch is a Z-Wave Switch module specifically used to enable Z-Wave command and control (on/off) of any plug-in tool.
- Product identifier
- HKZW-SW02
- Countries / regions
- United States of America
- Certification number
- ZC10-17045544
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 151
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_SCENE_ACTUATOR_CONF
- Supported / controlled meter types
- Meter Type Rate Type Description Electric meter
- Value white firmware updatable value updatable by consumer by rf switch load capacity watts value 1800 electric load type value incandescent mlv (magnetic) led inductive (e.g. motor) supported meter type value electric energy association groups
- Group Number Maximum Nodes Supported End Point ID Description 1
- From to description 0 0 the function is disabled. 1 65535 the threshold value 152 percentage threshold of power report power percentage threshold to be interpreted, when change value of the load power exceeds the setting threshold, the smart switch will send meter report to association device (group lifeline). 0 1 0 0 10 from to description 0 0 the function is disabled. 1 255 the threshold value 170 reset parameter no.171 and 172 parameter no.171 and 172 will be restored to default settings. 0 1 0 0 0 from to description 85 85 parameter no.171 and 172 will be restored to default settings. 172 energy report frequency the interval of sending energy report to association device (group lifeline). 0 4 0 0 300 from to description 0 0 the function is disabled. 5 2678400 the interval time of energy report 173 voltage report frequency the interval of sending voltage report to association device (group lifeline). 0 4 0 0 0 from to description 0 0 the function is disabled. 5 2678400 the interval time of voltage report 174 electricity report frequency the interval of sending electricity report to association device (group lifeline). 0 4 0 0 0 from to description 0 0 the function is disabled. 5 2678400 the interval time of electricity report 24 notification when load status change smart switch can send notifications to association device (group lifeline) when state of smart switch’s load change. 0 1 0 0 1 from to description 0 0 the function is disabled. 1 1 send basic report. 2 2 send basic report only when load condition is not changed by z wave command. texts