- Name
- NA Smart Plug(Z-Wave)
- Brand
- LEEDARSON
- Features
- Feature Values Supported Meter Type
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_ALWAYS_ON
- User icon
- 0x0701
- Categories
- Energy Meters, All Lighting Devices, On/Off Switches/Devices
- Product id
- 0x000B
- S2 classes
- S2_UNAUTHENTICATED
- Device type
- On/Off Power Switch
- Oem version
- HW: 1 FW: 1.00
- Library type
- SLAVE_ENHANCED_232
- Supports nwi
- Yes
- Installer icon
- 0x0701
- Z wave version
- 6.71.01
- Frequency plans
- US: 916.00MHz, 908.40MHz
- Manufacturer id
- 0x0300
- Product type id
- 0x0200
- Long description
- Smart Plug can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. Smart Plug is also a security Z-Wave device and supports the Over The Air (OTA) feature for the product’s firmware upgrade.
- Hardware platform
- ZM5101
- Short description
- Smart plug is a Z-Wave Switch plugin module specifically used to enable Z-Wave command and control (on/off) of any plug-in tool. It can report wattage consumption or kWh energy usage.
- Product identifier
- 6A-PL-VAB-A0
- Countries / regions
- United States of America
- Certification number
- ZC10-18076184
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 3
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
- Supported / controlled meter types
- Meter Type Rate Type Description Electric meter
- Value electric energy switch type value push button z wave scene type value scene firmware updatable value updatable by consumer by rf switch load capacity watts value 2300 association groups
- Group Number Maximum Nodes Supported End Point ID Description 1
- From to description 0 0 the function is disabled. 1 1 send basic report. 2 2 send basic report only when load status is not changed by z wave command. 4 led load indicator mode selection configure led display mode to prevent light pollution at night. 0 1 0 0 0 from to description 0 0 the led status follows the load change. 1 1 when operating the load, the led lights for 5 seconds and then turns off. 104 setting time for sending meter report (current) the interval time of sending meter report (current) to associated device (group lifeline). 0 4 0 0 0 from to description 5 2678400 available settings 0 0 the function is disabled 2 setting device status after power failure define how the plug reacts after the power supply is back on. 0 1 0 0 0 from to description 0 0 smart plug memorizes its state after a power failure. 1 1 smart plug does not memorize its state after a power failure. connected device will be on after the power supply is reconnected. 2 2 smart plug does not memorize its state after a power failure. connected device will be off after the power supply is reconnected. 17 the value here represents minimum change in wattage percent (in terms of percentage) for a meter report (watt) to be sent when the change value of the load power exceeds the setting value, smart plug will send meter report to associated device (group lifeline). 0 1 0 0 10 from to description 128 1 255% to 128% 128 127 available settings 0 0 the function is disabled 1 127 1% to 127% 100 setting the parameters 101~104 to the default states. setting the parameters 101~104 to the default states. 0 1 0 0 85 from to description 85 85 available settings 101 setting time for sending meter report (watt) the interval time of sending meter report (watt) to associated device (group lifeline). 0 4 0 0 600 from to description 0 0 the function is disabled. 5 2678400 available settings 102 setting time for sending meter report (kwh) the interval of sending meter report (kwh) to association device (group lifeline). 0 4 0 0 3600 from to description 0 0 the function is disabled. 5 2678400 available settings 103 setting time for sending meter report (voltage) the interval of sending meter report (voltage) to association device (group lifeline). 0 4 0 0 0 from to description 0 0 the function is disabled 5 2678400 available settings 254 enable/disable the configuration command lock/unlock all configuration parameters. 0 1 0 0 0 from to description 0 0 unlock. 1 1 lock. 1 overcurrent protection smart plug keep detecting the load power, once the ac current exceeds 16.5 a for more than 4 seconds, smart plug's relay will turn off. 0 1 0 0 1 from to description 0 0 the function is disabled 1 1 the function is enabled. texts