- Name
- Valves Controller with Water Meter
- Brand
- Philio
- Features
- Feature Values Color
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_ALWAYS_ON
- User icon
- 0x0700
- Categories
- All Lighting Devices, On/Off Switches/Devices
- Product id
- 0x0076
- S2 classes
- S2_UNAUTHENTICATED
- Device type
- On/Off Power Switch
- Oem version
- HW: 1 FW: 1.01
- Library type
- SLAVE_ENHANCED_232
- Product line
- Philio Z-Wave Products
- Supports nwi
- Yes
- Installer icon
- 0x0700
- Z wave version
- 6.81.03
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x013C
- Product type id
- 0x0001
- Long description
- This valves controller PAB04 is a security enabled wireless switch, based on Z-Wave Plus technology. Z-Wave Plus TM enabled devices displaying the Z-Wave Plus TM logo can also be used with it regardless of the manufacturer, and can also be used in other manufacturer’s Z-Wave TM enabled networks. Remote On/Off control of the connected valve is possible with other manufacturer’s wireless Controller. Each switch is designed to act as a repeater. Repeaters will re-transmit the RF signal to ensure that the signal is received by its intended destination by routing the signal around obstacles and radio dead spots. Because PAB04 supports Security Command Class, it can learn with Secured controller. Its functionality and supported command classes is identical when included as a secure and non-secure device. Connect PAB04 with an external water meter which can output pulse signals. PAB04 is able to detect instance water flow and the accumulated water.
- Hardware platform
- SD3502
- Short description
- This valves controller PAB04 is a security enabled wireless switch, based on Z-Wave Plus technology. Connect PAB04 with an external water meter which can output pulse signals. PAB04 is able to detect instance water flow and the accumulated water.
- Product identifier
- PAB04-1
- Countries / regions
- European Union
- Supports smart start
- Yes
- Certification number
- ZC10-20026864
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 1
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
- Supported multilevel sensors
- Multilevel Sensor Type Water flow
- Supported / controlled meter types
- Meter Type Rate Type Description Water meter
- Value white firmware updatable value updatable by consumer by rf association groups
- Group Number Maximum Nodes Supported End Point ID Group Name Profile Description 1
- From to description 1 1 1 : us gallon 2 2 2. kl 2 threshold of accumulated water flow when the accumulated water is over the threshold of accumulated water flow, pab04 will send meter report of its accumulated water flow (kl or us gallon) to group1 nodes. for example : if the threshold of accumulated water flow is set as 1 kl. pab04 will send meter report whenever it detects the accumulated water flow crossing over 1 kl、2 kl、3 kl、‧‧‧etc. 1 2 0 255 1 from to description 0 0 0 : disable accumulated meter report 1 255 1~255 : 1~255 us gallon or kl 3 differential of instant water flow when the variation of instant water flow is over the differential, pab04 will send multilevel sensor report (liter/h) to group1 nodes. in order to avoid too frequent report, it will not report when the instant water flow vary lower than the configured percentage of one liter. 1 1 0 100 10 from to description 0 0 0 : disable instant water flow report 1 100 1~100 : 1% ~ 100% 4 pulse count per liter the calculation of accumulated water flow and instant water flow is based on this value of the attached meter. check the specification of the water meter, you can find pulse frequency. for example : 7.5 q, q is flow rate in l/min. then the pulse count per liter will be 450, this value is count from 7.5 (l/min) multiply 60 seconds. 1 2 1 32767 450 from to description 1 32767 450 pulse/l 5 relay control mode if the relay control mode is set as 0 (nc), it will turn on the valve by closing the relay contact. if the relay control mode is set as 1 (no), it will turn on the valve by opening the relay contact. 1 1 0 1 0 from to description 0 0 0 : nc 1 1 1 : no 6 periodic auto report timer the auto report timer define how long will pab04 report the meter report of accumulated water flow. at the same time it also sand the multilevel sensor report of instant water flow and switch binary report of the state of the connected valve. 1 2 0 1440 60 from to description 0 0 0 : disable periodic auto report 1 1440 1~1440 :1min ~ 1440 min texts