- Name
- In Wall Single relay(1way) switch module
- Brand
- Philio
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_ALWAYS_ON
- User icon
- 0x0700
- Categories
- All Lighting Devices, On/Off Switches/Devices
- Product id
- 0x0010
- Device type
- On/Off Power Switch
- Oem version
- HW: 1 FW: 1.12
- Library type
- SLAVE_ENHANCED_232
- Supports nwi
- Yes
- Installer icon
- 0x0700
- Z wave version
- 6.51.06
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x013C
- Product type id
- 0x0001
- Long description
- This in-wall switch module is a transceiver which is a security enabled device which based on Z-Wave Plus technology, and it is fully compatible with any Z-WaveTM enabled network. Mini size design let the module can easily hide itself into the wall box and that will be good for the house decoration. Since PAN05 supports Security Command Class, it can learn with Secured controller. Its functionality and supported command classes is identical when included as a secure and non-secure device. There are many kind of application by using the module to switch Load On and Off, one main application is the light control. If connect the COM terminal directly to AC Line terminal, the new smart relay calibration technology can reduce the inrush current caused by the load and let the module work perfectly with many kind of light like incandescent, fluorescent and LED light. This module can also connect to alternative power supply like DC 12V to switch on/off 12V MR-16 light. Adding to Z-WaveTM Network In the front casing, there is an on/off button with LED indicator below which is used to toggle switch on and off or carries out add, remove, reset or association. When first power applied, its LED flashes on and off alternately and repeatedly at 0.5 second intervals. It implies that it has not been assigned a node ID and start auto inclusion. Auto Inclusion The function of auto inclusion will be executed as long as the in wall switch does not have Node ID and just connect the switch to main power. Note: Auto inclusion timeout is 2 minute during which the node information of explorer frame will be emitted once every several seconds. Unlike “Add” function as shown in the table below, the execution of auto inclusion is free from pressing the On/Off button on the Switch.
- Hardware platform
- SD3502
- Short description
- This in-wall switch module is a transceiver which is a security enabled device which based on Z-Wave Plus technology, and it is fully compatible with any Z-WaveTM enabled network.
- Association groups
- Group Number Maximum Nodes Supported End Point ID Description 1
- Product identifier
- PAN05-1B
- Countries / regions
- European Union
- Certification number
- ZC10-16025010
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 1
- Supports explorer frames
- Yes
- From to description 1 1 1 : edge mode 2 2 2 : pulse mode 3 3 3 : edge toggle mode 2 restore switch state mode whenever the ac power reconnected to pan05, it will set the switch to off、on or last switch state, default value is last switch state. 0 1 0 0 1 from to description 0 0 0 : switch off 1 1 1 : last switch state 2 2 2 : switch on 3 manual on/off mode the on/off function of s1、s2 and learn switch can be disabled or enabled by this parameter, default value is enable. but the learning operation won’t be affected. when manual on/off function is disabled, the rf command can only switch on but not off. this is useful function for keeping the device in switch on state. 0 1 0 0 1 from to description 0 0 0:disable manual on/off 1 1 1:enable manual on/off 4 led indication mode 1. show switch state:led on for switch on and off for switch off. the default value is show switch state. 2. show night mode:led off for switch on and on for switch off. 3. one flash mode:when the state of switch changes, led will be on only one second, then led keeps off. 0 1 0 0 1 from to description 1 1 1:show switch state 2 2 2:show night mode 3 3 3 : one flash mode 5 auto off timer when auto off timer is equal to 0, the auto off function will be disabled. whenever the switch is set to on, the auto off timer begin to count down. after the timer counts to zero, pan05 will switch off automatically. the default value is disable auto off function. 0 2 0 0 0 from to description 0 0 0:disable auto off function 1 32767 1 0x7 fff:1 ~ 32767seconds 6 rf off command mode whenever a rf off command is received, basic set、binary switch set、switch all off, it could be interpreted as switch off、switch on、switch toggle, or it would be ignored. the default value is switch off. 0 1 0 0 0 from to description 0 0 0:switch off 1 1 1:ignore 2 2 2:switch toggle 3 3 3:switch on 11 manual switch report mode whenever pan11 is manually switch on or off, it will send binary switch report to the node of group1. the default setting is enable the function. 0 1 0 0 1 from to description 0 0 0 : disable 1 1 1 : enable texts