- Name
- In Wall Dual relay(1 way) switch module
- Brand
- Philio
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_ALWAYS_ON
- Categories
- All Lighting Devices, On/Off Switches/Devices
- Product id
- 0x0013
- Device type
- On/Off Power Switch
- Oem version
- 01
- Library type
- SLAVE_ENHANCED_232
- Supports nwi
- Yes
- Z wave version
- 6.51.02
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x013C
- Product type id
- 0x0001
- Long description
- This in-wall switch module is a transceiver which is a Z-Wave PlusTM enabled device and is fully compatible with any Z-WaveTM enabled network. Mini size design let the module can easily hide itself into the wall box and that will be good for the house decoration. There are many kind of application by using the module to switch Load On and Off , one main application is the light control. If connect the com port directly to AC Line terminal ,the new smart relay calibration technology can reduce the inrush current caused by the load and let the module work perfectly with many kind of light like incandescent, fluorescent and LED light. This module can also connect to alternative power supply like DC 12V to switch on/off 12V MR-16 light.
- Hardware platform
- SD3502
- Short description
- This in-wall switch module is a transceiver which is a Z-Wave PlusTM enabled device and is fully compatible with any Z-WaveTM enabled network. Mini size design let the module can easily hide itself into the wall box and that will be good for the house decoration. There are many kind of application by using the module to switch Load On and Off , one main application is the light control.
- Association groups
- Group Number Maximum Nodes Supported End Point ID Description 2
- Product identifier
- PAN06-1A
- Countries / regions
- European Union
- Certification number
- ZC10-14120009
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 1
- Supports explorer frames
- Yes
- From to description 1 1 select relay1 : only relay1 can be controlled and report. 2 2 select relay2 : only relay2 can be controlled and report. 3 3 select relay1 & relay2 :relay1 and relay2 can be controlled and report at the same time. 2 edge / pulse / edge toggle mode manual switch s1 and s2 can set to edge mode or pulse mode or edge toggle mode, default value is edge mode. 0 1 0 0 1 from to description 1 1 edge mode: this mode is suitable for the bi stable wall switch that has indicator point on the switch, and the same position correspond to same state of relay1 and relay2. if the pan06 relay change the state because of receiving z wave rf command, it may need two times of change (switch on to off or switch off to on) to let relay back to the correspond state. 2 2 pulse mode: this mode is suitable for the toggle type wall switch to swap the state of relay1 or relay2. 3 3 edge toggle mode: this mode is suitable for the normal bi stable switch, every time when change the state of the wall switch will also swap the state of relay1 or relay2 3 restore switch state mode whenever the ac power return from lost, pan06 will restore the switch state which could be switch off、last switch state、switch on. the default setting is last switch state. 0 1 0 0 1 from to description 0 0 switch off 1 1 last switch state 2 2 switch on 4 auto off timer whenever pan06 switches to on, the auto off timer begin to count down. after the timer decrease to zero, it will switch to off automatically. however if auto off timer is set as 0, the auto off function will be disabled. the default setting is 0. 0 2 0 0 0 from to description 0 0 disable auto off function 1 32767 1s ~ 32767s 5 rf off command mode whenever a switch off command, basic set、binary switch set、switch all off, is received, it could be interpreted as 4 variety of commands. 0 1 0 0 0 from to description 0 0 switch off : it switches to off state. the default setting is switch off. 1 1 ignore : the switch off command will be ignored. 2 2 switch toggle : it switches to the inverse of current state. 3 3 switch on : it switches to on state. 6 existence of endpoint3 the endpoint3 of multi channel command class is related to relay1 and relay2. it may be redundant for the need to control relay1 or relay2 individually. when the existence of endpoint3 is set as 0, the endpoint3 of multi channel command class will be disabled. the default value is 1. 0 1 0 0 1 from to description 1 1 endpoint3 exist 2 2 no endpoint3 texts