- Name
- Smart Energy Plug In Switch
- Brand
- Philio
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_ALWAYS_ON
- Categories
- Energy Meters, All Lighting Devices, On/Off Switches/Devices
- Product id
- 0x0011
- Device type
- On/Off Power Switch
- Oem version
- 01
- Library type
- SLAVE_ENHANCED_232
- Supports nwi
- Yes
- Z wave version
- 6.51.00
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x013C
- Product type id
- 0x0001
- Long description
- This plug-in ON/OFF switch PAN11 is a security enabled wireless switch, based on Z-Wave Plus™ technology. Z-Wave Plus™ enabled devices displaying the Z-Wave Plus™ logo can also be used with it regardless of the manufacturer, and can also be used in other manufacturer’s Z-Wave™ enabled networks. Remote On/Off control of the connected load is possible with other manufacturer’s wireless controller. Each switch is designed to act as a repeater. Repeaters will re-transmit the RF signal to ensure that the signal is received by its intended destination by routing the signal around obstacles and radio dead spots. Because PAN11 supports Security Command Class, it can learn with Secured controller. Its functionality and supported command classes is identical when included as a secure and non-secure device. This plug-in ON/OFF switch is able to detect instance wattage (3000W/CE/CN, 1500W/UL/TW/JP) and overload current (14.5A) of connected lights or appliances. When detecting overload state, the Switch will be disabled and its On/Off button will be lockout of which LED will flash quickly. However, unplug and re-connect the switch will reset its overload condition to normal status.
- Hardware platform
- SD3502
- Short description
- This plug-in ON/OFF switch PAN11 is a security enabled wireless switch, based on Z-Wave Plus™ technology. This plug-in ON/OFF switch is able to detect current wattage and overload wattage of connected lights or appliances.
- Association groups
- Group Number Maximum Nodes Supported End Point ID Description 1
- Product identifier
- PAN11-1A
- Countries / regions
- European Union
- Certification number
- ZC10-14080016
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 2
- Supports explorer frames
- Yes
- From to description 1 32767 6*10min=1 hour 7 led indication mode 1. show switch state:when switch is on, led is on. when switch is off, led is off. the default setting is show switch state. 2. show night mode:when switch is on, led is off. when switch is off, led is on. 3. one flash mode:when the state of switch changes, led will be on only one second, then led keeps off. 0 1 0 0 1 from to description 1 3 1 : show switch state 2 : show night mode 3 : one flash mode 8 auto off timer whenever pan11 switches to on, the auto off timer begin to count down. after the timer decrease to zero, it will switch to off automatically. however if auto off timer is set as 0, the auto off function will be disabled. the default setting is 0. 0 1 0 0 0 from to description 0 32767 0 : disable auto off function 1 0x7 fff : 1s ~ 32767s 6 mode of switch off function when the mode of switch on/off is set to 0, any command of switch off will be disabled and the on/off function of include button will be disabled. the default setting is enable mode. 0 1 0 0 1 from to description 0 1 0 : disable 1 : enable 1 watt meter report period if the setting is configured for 1hour (set value =720), the pan11 will report its instant power consumption every 1 hour to group1 node. the maximum interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr). 0 2 0 0 720 from to description 1 32767 720*5s=3600s=1 hour 5 restore switch state mode whenever the ac power return from lost, pan11 will restore the switch state which could be switch off、last switch state、switch on. the default setting is last switch state. 0 1 0 0 1 from to description 0 2 0 : switch off 1 : last switch state 2 : switch on 4 threshold of kwh for load caution this is a warning when the kwh of load over the preset threshold value, if the setting value is 10000, when the accumulated power consumption of relay1 over this value, pan11 will send kwh meter report to warn the group1 node, minimum value is 1 kwh and default value is 10000 k wh. 0 2 0 0 10000 from to description 1 10000 1 kwh ~ 10000 kwh 9 rf off command mode whenever a switch off command, basic set 、 binary switch set 、 switch all off, is received, it could be interpreted as 4 variety of commands. 1. switch off:it switches to off state. the default setting is switch off. 2. ignore:the switch off command will be ignored. 3. switch toggle:it switches to the inverse of current state. 4. switch on:it switches to on state. 0 1 0 0 0 from to description 0 3 0 : switch off 1 : ignore 2 : switch toggle 3 : switch on 3 threshold of current for load caution this is a warning when the current of load over the preset threshold value, if the setting value is 1300, when the load current of relay1 over this value, pan11 will send current meter report to warn the group1 node, the range of the setting value is from 10 to 1300,and the default value is 1300. 0 2 0 0 1300 from to description 10 1300 1300*0.01 a = 13 a texts