- Name
- In Wall Dual relay switch module
- Brand
- Philio
- Features
- Feature Values Switch Load Capacity Current
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_ALWAYS_ON
- User icon
- 0x0700
- Categories
- All Lighting Devices, On/Off Switches/Devices
- Product id
- 0x0077
- S2 classes
- S2_UNAUTHENTICATED, S2_AUTHENTICATED
- Device type
- Binary Switch
- Oem version
- HW: 1 FW: 1.01
- Library type
- SLAVE_ENHANCED_232
- Product line
- Philio Z-Wave Products
- Supports nwi
- Yes
- Installer icon
- 0x0700
- Z wave version
- 7.15.1
- Frequency plans
- EU: 869.85MHz, 868.40MHz
- Manufacturer id
- 0x013C
- Product type id
- 0x0001
- Long description
- This in-wall dual relay switch module is a transceiver which is a Z-Wave Plus TM enabled device and is fully compatible with any Z-Wave TM enabled network. Mini size design let the module can easily hide itself into the wall box and that will be good for the house decoration. There are many kind of application by using the module to switch AC power On and Off, one main application is the light control. The new smart relay calibration technology can reduce the inrush current caused by the load and let the module work perfectly with many kind of light like incandescent, fluorescent and LED light. This in-wall switch module is able to detect Instant power wattage and overload current (7.5A with resistive load) of connected light or appliances. When detecting overload state, the Module will be disabled and its On/Off button will be lock-out of which LED will flash quickly. However, disconnect and re-connect the Module will reset its overload condition to normal status. This product can be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers. All mains operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
- Hardware platform
- ZGM130
- Short description
- This in-wall dual relay switch module is a transceiver which is a Z-Wave Plus TM enabled device and is fully compatible with any Z-Wave TM enabled network.
- Product identifier
- PAN30-1
- Countries / regions
- European Union
- Supports smart start
- Yes
- Certification number
- ZC12-21060234
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 2
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_CONFIGURATION_V4
- Supported notification types
- Notification Type Event / State Power Management
- Supported / controlled meter types
- Meter Type Rate Type Description Electric meter
- Value 6.5 amps color value white firmware updatable value updatable by consumer by rf association groups
- Group Number Maximum Nodes Supported End Point ID Group Name Profile Description 2
- From to description 0 0 the auto report function of meter kwh will be disabled. 1 32767 6*10min= 1 hour 3 threshold of current for load caution this is a warning when the current of load over the preset threshold value, if the setting value is 750, when the load current of relay1 or relay2 over this value, pan30 will send current meter report to the node of correspond group, the range of the setting value is from 10 to 750, and the default value is 750. 2 2 10 750 750 from to description 10 750 750*0.01 a = 7.5 a 4 threshold of kwh for load caution this is a warning when the kwh of load over the preset threshold value, if the setting value is 10000, when the accumulated power consumption of relay1 or relay2 over this value, pan30 will send kwh meter report command to the node of correspond group, minimum value is 1 kwh and default value is 10000 k wh. 2 2 1 10000 10000 from to description 1 10000 1 kwh ~ 10000 kwh 6 restore switch state mode whenever the ac power return from lost, pan30 will restore the switch state which could be switch off、last switch state、switch on. the default setting is last switch state. 3 1 0 2 1 from to description 0 0 switch off 1 0 last switch state 2 0 switch on 5 external switch mode manual switch s1 and s2 can set to edge mode or pulse mode or edge toggle mode, default value is edge mode. 3 1 1 3 1 from to description 1 0 edge mode 2 0 pulse mode 3 0 edge toggle mode 7 watt differential report mode it will trigger a watt report when the variation of watt value is over the preset percentage. 3 1 0 4 1 from to description 0 0 the function of watt differential report will be disabled. 1 0 5% 2 0 10% 3 0 15% 4 0 20% 1 watt meter report period if the setting is configured for 1hour (set value =720), the pan30 will report its instant power consumption every 1 hour to the node of correspond group. the maximum interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr). if the setting value is 0, the auto report function of meter watt will be disabled. 2 2 0 32767 720 from to description 0 0 the auto report function of meter watt will be disabled. 1 32767 720*5s=3600s= 1 hour texts