- Name
- Flood Multisensor
- Brand
- Philio Technology
- Features
- Feature Values Supported Notification Types
- Documents
- Category Description File Manual_Primary_Lang
- Role type
- ROLE_TYPE_SLAVE_SLEEPING_REPORTING
- User icon
- 0x0C05
- Categories
- Sensors
- Product id
- 0x001F
- Device type
- Notification Sensor
- Oem version
- HW: 1 FW: 1.14:01.12
- Library type
- SLAVE_ENHANCED_232
- Supports nwi
- Yes
- Installer icon
- 0x0C05
- Z wave version
- 6.51.06
- Frequency plans
- RU: 869.00MHz
- Manufacturer id
- 0x013C
- Product type id
- 0x0002
- Long description
- It is the Z-WaveTM plus product, it support the security, OTA... Those newest features of the Z-WaveTM technology. Z-WaveTM is a wireless communication protocol designed for home automation, specifically to remotely control applications in residential and light commercial environments. The technology uses a low-power RF radio embedded or retrofitted into home electronics devices and systems, such as lighting, home access control, entertainment systems and household appliances
- Hardware platform
- SD3502
- Short description
- The flood multisensor PAT02 has flood, temperature and humidity, 3 sensors function in one, based on Z-WaveTM technology.
- Product identifier
- PAT02-1A
- Countries / regions
- Russian Federation
- Certification number
- ZC10-18036035
- Radio range z wave (m)
- 40
- Configuration parameters
- Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 5
- Supports explorer frames
- Yes
- Supported command classes
- Identifier Name Key Version COMMAND_CLASS_SENSOR_MULTILEVEL_V5
- Controlled command classes
- Identifier Name Key Version COMMAND_CLASS_BASIC
- Supported multilevel sensors
- Multilevel Sensor Type Air temperature
- Supported notification types
- Notification Type Event / State Water Alarm
- Value water alarm home security sensors value air temperature humidity association groups
- Group Number Maximum Nodes Supported End Point ID Description 1
- From to description 5 5 bit5: disable the temperature report after event triggered. (1:disable, 0:enable) 3 3 bit3: setting the temperature scale. 0: fahrenheit, 1:celsius 0 0 bit0: disable the flood function. 6 mult sensor function switch multisensor function switch. using bit to control. bit6: disable the humidity report after event triggered. (1:disable, 0:enable) 0 1 0 0 0 from to description 6 6 bit6: disable the humidity report after event triggered. (1:disable, 0:enable) 7 customer function customer function switch, using bit control. bit3: disable send out basic off after the flood event cleared. (1:disable, 0:enable) bit4: notification type, 0: using notification report. 1: using sensor binary report bit5: disable multi cc in auto report. (1:disable, 0:enable) bit6: disable to report battery state when the device triggered. (1:disable, 0:enable) 0 1 0 0 0 from to description 3 3 bit3: disable send out basic off after the flood event cleared. (1:disable, 0:enable) 4 4 bit4: notification type, 0: using notification report. 1: using sensor binary report. 5 5 bit5: disable multi cc in auto report. (1:disable, 0:enable) 6 6 bit6: disable to report battery state when the device triggered. (1:disable, 0:enable) 23 humidity differential report the humidity differential to report. 0 means turn off this function. the unit is percentage. enable this function the device will detect every 10 seconds. 0 1 0 0 5 from to description 0 60 the humidity differential to report. 0 means turn off this function. the unit is percentage. enable this function the device will detect every 10 seconds. 1 basic set off level setting the basic command value. when the flood trigger off(0x00), send the basic cc to the group 2. 0 1 0 0 0 from to description 128 127 setting the basic command value. when the flood trigger off(0x00), send the basic cc to the group 2. 2 basic set on level setting the basic command value. when the flood trigger on(0x ff), send the basic cc to the group 2. 0 1 0 0 127 from to description 128 127 setting the basic command value. when the flood trigger on(0x ff), send the basic cc to the group 2. texts